Rockwell-automation 2071-Axx Kinetix 3 Component Servo Drive Serial Ho Manuel d'utilisateur Page 31

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 146
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 30
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013 31
Chapter 3
General Commands (ASCII)
This chapter defines the general ASCII commands available to control a
Kinetix 3 drive.
Read Parameter (SET)
Attribute Value
Command SET
Description Read parameter value
Format STX ID # SET PPP : BSS ETX
Data Argument Description
PPP Parameter #; for example, [Pr - 2.03]
, PPP=203=0x0CB
Refer to this chapter, Appendix A
, Standard Drive Parameters,
and Appendix B, Indexing Drive Parameters for a available
parameter descriptions.
Response Format STX ID $SET V : BSS ETX
Response Data Argument Description
V Bit-field type = 4-byte hexadecimal value.
Integer type = Signed integer of variable length
Vue de la page 30