Publication 2092-RM001A-EN-P — March 2005
2-42 Command Reference
[Pr – 9.16] Electrical Cycle Length
[Pr – 9.17] Encoder Lines / Meter
[Pr – 9.18] Maximum Linear Speed
[Pr – 9.19] Motor Thermal Protection Enable
[Pr – 9.20] Motor Thermostat
Ultraware Name: General: Electrical Cycle
Range: 100 to 10000
Units: Millimeters * 10
Operating Mode: All
Ultraware Name: Feedback: Lines/Meter
Range: 4000 to 10000000
Units: Lines
Operating Mode: All
Ultraware Name: Rating: Maximum Speed
Range: 32 - 2
15
- 1
Units: meters per second * 256
Operating Mode: All
Ultraware Name: Thermal: Software Protection
Range: 0 to 1
Units Description
0 No - Disabled
1 Yes - Enabled
Operating Mode: All
Ultraware Name: Thermal: Integral Thermostat
Range: 0 to 1
Units Description
0 No
1 Yes
Operating Mode: All