Publication 2092-RM001A-EN-P — March 2005
Command Reference 2-3
Fault Reset (RST)
Monitor Variable (MDM)
Command: RST
Description: Clear fault
Format: STX ID # RST : BSS ETX
Response: ACK
Usage Note: Fault Reset will have no effect if action was not taken to resolve the
problem causing the fault.
Command: MDM
Description: Monitor variables
Format: STX ID # MDM P1 P2 P3 P4 P5 : BSS ETX
Data: Argument Description
P1-P5
Variables to monitor.
Refer to Monitor Variables on page A-3 for the
list of variables.
Usage Note: MDM command can monitor up to 5 variables. See Appendix A for
the list of variables.
Response Format: STX ID $ MDM V1&V2&V3&V4&V5 : BSS ETX
Response Data: Argument Description
V1 to V5 Variable values are 4 or 8 bytes signed
Vue de la page 14