Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 47
Chapter
3
FANUC CNC Configuration
In this chapter you initially configure your FANUC 30i-B, 31i-B, 32i-B, or 35i-B CNC, set up the CNC
communication, and create a new project file for your CNC application. The intent is to provide a quick setup
for an EtherNet/IP connection between a Rockwell Automation ControlLogix/GuardLogix PLC and a
FANUC 30i-B, 31i-B, 32i-B, or 35i-B CNC.
The overall CNC configuration and parameterization is not being addressed by this quick start, and is the
responsibility of the machine tool builder.
Before You Begin
Complete your system architecture and hardware selection (refer to Chapter 1).
Complete your system layout and wiring (refer to Chapter 2).
What You Need
The CNC Machining Accelerator Toolkit DVD, publication IASIMP-SP018. For a copy of the DVD,
contact your local Rockwell Automation distributor or sales representative
FANUC LADDER III software, version 6.8 or later
USB flash drive
FANUC Series 30i/31i/32i/35i –MODEL B, EtherNet/IP Adapter function, publication
FANUC Series 30i/31i/32i/35i -MODEL B, FANUC Power Motion i -MODEL A EtherNet/IP Scanner
function, publication TMN11095E_B[email protected]