Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 257
Add Other Devices to the Equipment Status Faceplate Appendix C
10. Expand the Value1_Grp group.
11. Double-click the Value1_Str object to open its Numeric
DIsplay Properties.
12. Click the Connections tab and
assign a tag to the numeric
display object.
13. Double-click the Units1_Str
object to open its String Display
Properties.
14. Click the Connections tab and
assign a tag in the controller that
contains a string for the units, or
simply type in a static string by
enclosing in quotes.
In this example, “degrees” is the
tag name.
15. Repeat step 11 and step 13 for
each Valuex_Grp group in your row.