Data Manipulation Instructions
Chapter 6
615
Figure 6.16
Divide
Instruction
||
13
(
: )
000
111 067
| G |
050
140
| G |
025
141
Must be true to allow
arithmetic operation
( : )
002
066
Arithmetic instructions are entered into memory with the PLC-2/30
Processor in the program mode. When entered, these instructions will be
intensified and blinking. They will continue to blink until the word address
is entered. Refer to Table 6.B for a summary of these instructions.
A 3-, 4- or 5-digit default word address (010, 0010 or 00010) will be
displayed above the instruction provided the data table is expanded
accordingly. When the data table is expanded to a 5-digit word address,
the 5-digit default address will be displayed. To enter a 3- or 4-digit word
address when 4 or 5 digits are displayed, the programmer must enter
leading zeros before entering the word address.
6.5
Programming Arithmetic
Instructions