1–12 Getting Started
1336 FORCE — 5.9 August 1995
3. Upon completion, select the Connect to Drive option from the
DriveBlockEditors pull-down D
rive menu and re-enter the
station number to go online.
4. Once online, verify that values are changing at the Rate Limiter
function block’s output node.
Step 8 — Link Analog Output Parameters to Function
Block Nodes
Enter the DriveManager program to link linear parameters.
1. Enter a scale factor value of 2048 for Parameters 401 and 405.
The value 2048 will be shown in the Internal units field shown
below.