132 Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
Chapter 4 Bulletin 290E/291E/294E Programmable Parameters
TripLog4
This parameter provides the fifth last trip
to occur.
Parameter Number 22
Access Rule GET
Data Type UINT
Group Trip Status
Units
Minimum Value 0
Maximum Value 75
Default Value 0
SnapShotOutFreq
This parameter provides a snapshot
of output frequency at time of last trip.
Parameter Number 23
Access Rule GET
Data Type UINT
Group Trip Status
Units x.x Hz
Minimum Value 0
Maximum Value 999.9
Default Value 0
SnapShotOutAmps
This parameter provides a snapshot
of output current at time of last trip.
Parameter Number 24
Access Rule GET
Data Type UINT
Group Trip Status
Units x.xx Amps
Minimum Value 0
Maximum Value 4.60
Default Value 0
SnapShotOutVolts
This parameter provides a snapshot
of output voltage at time of last trip.
Parameter Number 25
Access Rule GET
Data Type UINT
Group Trip Status
Units x.x V AC
Minimum Value 0
Maximum Value 999.9
Default Value 0