Rockwell Automation Publication 290E-UM001B-EN-P - June 2012 105
Bulletin 290E/291E/294E Programmable Parameters Chapter 4
Bit
Function
1514131211109876543210
——————————————— X RunForward
—————————————— X RunReverse
————————————— X —— ResetFault
———————— X X X X X ——— Reserved
——————— X ———————— Out00
—————— X ————————— Out01
————— X —————————— Out02
———— X ——————————— Out03
——— X ———————————— Out04
—— X ————————————— Out05
X X —————————————— Reserved
AuxIOStatus
The parameter provides the status of
hardware input/output points.
Parameter Number 8
Access Rule GET
Data Type WORD
Group Basic Status
Units
Minimum Value 0
Maximum Value 0x3F
Default Value 0
Bit
Function
1514131211109876543210
——————————————— X Pt00
—————————————— X Pt01
————————————— X —— Pt02
———————————— X ——— Pt03
——————————— X ———— Pt04
—————————— X ————— Pt05
XXXXXXXXXX—————— Reserved