9–29Diagnostic Counters
Publication
17706.5.16 - October 1996
1785KA5 DH+ Diagnostic Counters
This counter byte
Counts the number of
0
1 Timeouts that expired with no ACK received.
2 Transmit retries exhausted.
3 NAKs due to illegal protocol operations.
4 NAKs due to bad LSAPs.
5 NAKs due to memory available.
6
7
8
9 Duplicate tokens detected.
10 Duplicate nodes detected.
11 Token pass timeouts.
12 Token pass retries exhausted.
13 Claim token sequences entered.
14 Tokens claimed.
15 Bad CRC in received frame.
16
17
18 NAK due to no memory sent.
19
20
21 Frame transmissions received.
22 Receive frames aborted (noise).
23, 24 Messages successfully sent (low byte first).
25, 26 Messages successfully received (low byte first).
27, 28
29, 30
31, 32
33, 34
35
36 Number of active nodes.
A
shaded cell means the counter is present but not functional.