Publication 1761-UM006E-EN-P - August 2005
7-6 1761-NET-ENIW Web Server Capabilities
Figure 7.2 Example Write to First String on Second Data View Page
Integer Data
Integer data for the Data View pages is written to Node 202, offset
elements 0 to 27, as described in Table 7.3. Integers are displayed as
right-justified, signed decimal numbers from -32768 to +32767.
IMPORTANT
The 1761-NET-ENIW does not support either 485CIF
Writes or PLC2 (Unprotected Writes) for displaying
integer or floating-point device data. Instead, the
web page DST of the ENIW uses the SLC-type write
(Protected Type Logical Write with three address
fields), which allows the data type and element
index to be relevant.