Setting Up Your SLC Servo Module
7-5
7. Press Enter.
8. Press ESC three times to return to the top screen of the Offline
Ladder Editor screen.
9. Press F8 (Display).
10. Press F1 (addr).
11. Enter desired data table address.
12. Press Enter.
13. Enter parameters into Bit (B), Integer (N), or Float (F) files.
14. Press ESC to return to Offline Editor screen.
Configuring Your Processor Using APS Software
Configuring your processor involves assigning the SLC Servo Module
to an open slot in the chassis, setting the file length, and entering
parameters.
To assign your SLC Servo Module to an open slot:
1. Press F4 (OFFLINE CONFIG).
2. Select project file.
3. Press Enter.
4. Press F1 (OFFLINE PRG/DOC).
5. Press F1 (PROCESSOR FUNCTIONS).
6. Press F1 (CHANGE PROCESSOR).
7. Press F5 (CONFIG I/O).
8. Select an open slot.
9. Press F5 (MODIFY SLOT).
IMPORTANT
Use F1 to change the radix between binary and
decimal.