8-6
Control and Configuration Software V6.1
8.10 Monitoring Drive Indicators
The Drive Metering box displays six drive indicators for GV3000 or Liqui-Flo drives or
five drive indicators for FlexPak 3000 drives. The items displayed in the Drive Metering
box are dependent on drive type and regulation type.
Each drive metering value is displayed as a visual thermometer-type indicator and as
a numeric value. If the numeric value exceeds the range of the indicator, the indicator
moves slightly beyond the far right line in the indicator grid. The units (RPM, Amps,
etc.) shown in figure 8.1 are examples only. The actual units are defined by the drive
type are preset.
For: The following indicators are listed:
GV3000 or Liqui-Flo drives configured
for vector regulation
Selected reference
Motor speed
Motor current
Motor voltage
Motor torque
Output power
GV3000 or Liqui-Flo drives configured
for volts/hertz regulation
Selected reference
Output speed
Output frequency
Motor voltage
Motor current
Output power
FlexPak 3000 drives Selected reference
Motor speed
Armature volts
Motor current
Percent load