5-10
Control and Configuration Software V6.1
Step 3. Click Start Profile. The following message is displayed:
“Profile will run the motor alternating between xxx RPM for x.x sec and
xxx RPM for x.x sec. Acceleration time is x.x sec, deceleration time is x.x sec.
Select OK to run the motor using this profile, or Cancel to quit.”
Step 4. Click Ok to start the profile.
The drive will cycle between Speed 1 and Speed 2, staying at each speed for
the amount of time entered for Time 1 and Time 2. You can monitor results in
PC Scope (see chapter 9).
Step 5. Click Stop/Reset to stop the drive and the profile.
Some drive parameters (accel/decel) may be modified automatically in order
to run the profile. These values will be saved prior to being modified by this
function and the original values will be restored when Stop/Reset is selected.
This completes the Custom tuning process.