12Ć11
 







byte 1 data's location a byte is written
double byte
Note: Use this option to
write data to modules
that only support an
8Ćbit Multibus access.
2 data's location The low byte is written
first and then the high
byte.
integer (16Ćbits)
Note: Use this option to
write data from
modules that support
AutoMax addressing
and data conventions.
3 data's location as an even
address
A 16Ćbit word is
written from the
designated address.
double integer (32Ćbits) 4 data's location as an even
address
A 32Ćbit word is
written from the
designated address in
this order:
D MS 16Ćbit word
D LS 16Ćbit word
Vue de la page 262