7Ć4
7.1.2 Output
P
arameters for the Convert Integer Data to BCD Instruction
This table lists the outputs for the TO_BCD instruction and the variable type and data
type/range that each output supports.
Parameter
Description V
ariable T
ype Data Type/Range
ENO Use this output as the input to another instruction for
easily chaining multiple instructions. This output follows
the state of EN unless an error occurs.
Connect a contact, coil, or Boolean input of
another instruction.
Out This output contains the binary coded decimal equivalent
of the integer value of In.
D simple
D element of an array
BCD value of 0Ć9999
(integer) or
0Ć99999999
(double integer)