10.5.2 Output
P
arameters for the Array Shift Down Instruction
This table lists the outputs for the ASD instruction and the variable type and data
type/range that each output supports.
Parameter
Description V
ariable T
ype Data/Type Range
ENO Use this output as the input to another instruction for easiĆ
ly chaining multiple instructions. This output follows the
state of EN unless an error occurs.
Connect a contact, coil or Boolean parameter
of another instruction.
Out Enter the name of variable in which you want to store the
bottomĆmost element that was shifted out of the array.
This variable must be of the same data type as In.
D simple
D element of an
array
D integer
D double integer
D timer
(name.TPreset and
name.Elapsed)
D counter
(name.CPreset
and name.Current)