Creating Data Display Screens 7-9
ASCII
The screen for an ASCII format is shown below:
Each data display can only be 16 bit data or 2 characters. Multiple data
entries can be created in sequence up to 28 total.
Format Selection Description
Register Number The controller address to be monitored.
Character Count The number of characters (2 characters for each 16 bit
data address) to be displayed, up to a maximum of 2
characters. The initial byte of the address identified by the
register number is displayed first, then the second byte,
the first byte of the next higher sequential address, and so
on. To display 16 characters, a sequential block of eight 16
bit addresses is read by the MicroView.
First Character in LSB or
MSB
Indicates placement of first ASCII character to be read. If
LSB, the first character is in bits 0 to 7 of the register. If
MSB, the first character is in bits 8 to 15 of the register