Rockwell-automation 2707-NP2 MICROVIEW SOFTWARE PROGRAMMING MANUAL Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Rockwell-automation 2707-NP2 MICROVIEW SOFTWARE PROGRAMMING MANUAL. Rockwell Automation 2707-NP2 MICROVIEW SOFTWARE PROGRAMMING MANUAL User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 134
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - Software

MicroView Programming SoftwareCatalog No. 2707-NP2Programming Manual

Page 2 - Important User Information

Publication 2707-PM002B-EN-P 1-4 Using this ManualRockwell Automation SupportRockwell Automation offers support services worldwide, with over 7

Page 3 - Table of Contents

Publication 2707-PM002B-EN-P14-2 Transferring / Printing Application FilesDownloading an ApplicationThis section shows how to download an appli

Page 4 - Table of Contents ii

Publication 2707-PM002B-EN-PTransferring / Printing Application Files 14-3The MicroView Operating Menu appears.7. Highlight Download File to Mi

Page 5 - Table of Contents iii

Publication 2707-PM002B-EN-P14-4 Transferring / Printing Application FilesThe download begins and the following screen shows the progress of th

Page 6 - Table of Contents iv

Publication 2707-PM002B-EN-PTransferring / Printing Application Files 14-5Uploading an ApplicationThis section shows how to upload an applicati

Page 7 - Using this Manual

Publication 2707-PM002B-EN-P14-6 Transferring / Printing Application FilesThe MicroView Opening Menu Appears.8. Highlight Upload File From Micr

Page 8 - Intended Audience

Publication 2707-PM002B-EN-PTransferring / Printing Application Files 14-7The upload begins and the following screen shows the progress of the

Page 9 - Related Publications

Publication 2707-PM002B-EN-P14-8 Transferring / Printing Application FilesPrinting Application FilesThis section describes how to output a copy

Page 10 - Rockwell Automation

Publication 2707-PM002B-EN-PTransferring / Printing Application Files 14-93. You are then prompted for the type of output device. Select the d

Page 11 - Programming Software

Publication 2707-PM002B-EN-P14-10 Transferring / Printing Application Files

Page 12 - Installation Files

1 Publication 2707-PM002B-EN-PChapter 15Upgrading the Operating SystemChapter ObjectivesThis chapter describes how to update the MicroView operating s

Page 13 - Installing MicroView

1 Publication 2707-PM002B-EN-P Chapter 2Installing and Running the MicroView Programming SoftwareChapter ObjectivesThis chapter describes how to insta

Page 14

Publication 2707-PM002B-EN-P15-2 Upgrading the Operating SystemThe MicroView Opening Menu Appears.6. Highlight Upgrade Operating System and pre

Page 15

Publication 2707-PM002B-EN-PUpgrading the Operating System 15-39. If you select [N], the downloaded is aborted and the Opening menu is displaye

Page 16 - Running DPS

Publication 2707-PM002B-EN-P15-4 Upgrading the Operating System

Page 17 - Menu Conventions

1 Publication 2707-PM002B-EN-PAppendix AASCII Character SetASCII TableWhen ASCII characters are downloaded to the MicroView, they may appear different

Page 18 - Conventions

Publication 2707-PM002B-EN-PA-2 ASCII Character SetASCII Display Character Set (DEC 32 - 103)

Page 19 - Linking Application

Publication 2707-PM002B-EN-PASCII Character Set A-3ASCII Display Character Set (DEC 104 - 191)

Page 20

Publication 2707-PM002B-EN-PA-4 ASCII Character Set

Page 21 - Terminal

1 Publication 2707-PM002B-EN-PAppendix BApplication and Screen WorksheetsYou can use the worksheet templates on the following pages when designing you

Page 22 - MicroView File Types

Publication 2707-PM002B-EN-PB-2 Application and Screen WorksheetsMicroView Application Worksheet

Page 23 - Screen Types and Data

Publication 2707-PM002B-EN-PApplication and Screen Worksheets B-3MicroView Application Worksheet

Page 24 - Data Scaling

Publication 2707-PM002B-EN-P2-2 Installing and Running the MicroView Programming SoftwareSystem RequirementsVerify your computer is properly co

Page 25 - Scaling Formulas

Publication 2707-PM002B-EN-PB-4 Application and Screen WorksheetsMicroView Screen Worksheet2 Lines of 16 charactersScreen # _______Screen # ___

Page 26 - Application Example

Publication 2707-PM002B-EN-PApplication and Screen Worksheets B-5MicroView Screen Worksheet2 Lines of 16 charactersScreen # _______Screen # ___

Page 27 - Description of Example

Publication 2707-PM002B-EN-PB-6 Application and Screen Worksheets

Page 28 - Designing an Application

1 Publication 2707-PM002B-EN-PAppendix CMicroLogix Mnemonics in DPSThe MicroView supports all MicroLogix mnemonics for logical addressing to the sub-e

Page 29

Publication 2707-PM002B-EN-PC-2 MicroLogix Mnemonics in DPS.PE INTERRUPT PENDING.LS INTERRUPT LOST.IE INTERRUPT ENABLEC (Counter) .CU UP COUNTE

Page 30

1 Publication 2707-PM002B-EN-PAppendix DMicroLogix Data FormatsThe data selected for a controller address must reflect the same format as the data act

Page 31 - Opening Menu

Publication 2707-PM002B-EN-PD-2 MicroLogix Data FormatsFor example, the OFF(0) state of a bit might display “Pump is OFF”, and the ON(1) state

Page 32 - Applications

Publication 2707-PM002B-EN-PMicroLogix Data Formats D-316 Bit BCDThis data format displays a 16 bit register address as a 4 digit Binary Coded

Page 33 - Saving Application File

Publication 2707-PM002B-EN-PD-4 MicroLogix Data FormatsASCIIASCII data formats are fields up to 16 characters long. Each 16 bit address may con

Page 34

Publication 2707-PM002B-EN-P IndexAAccessoriesMicroView 2-2Advisorconfiguring 12-4Description 12-5update rate - PLC 12-12Applicationdownload 14-2editi

Page 35 - Using Screen Builder

Publication 2707-PM002B-EN-PInstalling and Running the MicroView Programming Software 2-3Installing MicroView Programming SoftwareThis section

Page 36 - Accessing Screen Types

Publication 2707-PM002B-EN-P 2 IndexDOSrequirement 2-2downloading 14-2DPSrunning 2-6DPS.EXE 2-2DPS_CFG.EXE 2-2EEditingscreens 5-4Entering regis

Page 37 - Publication 2711-PM002B-EN-P

Publication 2707-PM002B-EN-P Index 3PParameters window 2-8Print optionsall screens 14-9selected screens 14-9summary 14-9Printerforms 4-3Printin

Page 38 - Editing Screen Displays

Publication 2707-PM002B-EN-P 4 IndexTTelephone support number 2-6Text editing 5-4Transferring applications 14-2, 14-5UUpdate interval 12-3Upgra

Page 40 - Selecting Other Screens

Publication 2707-PM002B-EN-P - February 2001 7 40061-290-01(B)Supersedes Publication 2707-805 - May 1995 © 2001 Rockwell International Corporation.

Page 41 - Clearing Screens

Publication 2707-PM002B-EN-P2-4 Installing and Running the MicroView Programming Software5. Press any key (other than [Esc] ) to continue. This

Page 42 - Exiting Screen Builder

Publication 2707-PM002B-EN-PInstalling and Running the MicroView Programming Software 2-57. Press [Return] to install the DPS software in the \

Page 43 - Sub-Menu Screens

Publication 2707-PM002B-EN-P2-6 Installing and Running the MicroView Programming SoftwareRunning DPSTo run the MicroView Programming Software:1

Page 44 - Building a Menu

Publication 2707-PM002B-EN-PInstalling and Running the MicroView Programming Software 2-7Menu ConventionsThe following shows the format of DPS

Page 45 - Screen Builder

Publication 2707-PM002B-EN-P2-8 Installing and Running the MicroView Programming SoftwareScreen Building ConventionsApplication programs are wr

Page 46 - Creating a Menu Screen

Publication 2707-PM002B-EN-PInstalling and Running the MicroView Programming Software 2-9Cursor Status LineThe cursor status line is located be

Page 47 - Creating Data Display Screens

Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use

Page 48 - Data Display Screen

Publication 2707-PM002B-EN-P2-10 Installing and Running the MicroView Programming Software

Page 49 - Creating a Display Screen

1 Publication 2707-PM002B-EN-PChapter 3Designing Microview ApplicationsChapter ObjectivesThis chapter provides guidelines for creating MicroView appli

Page 50 - 16 Bit Signed Integer Shown

Publication 2707-PM002B-EN-P3-2 Designing Microview ApplicationsA major consideration when designing application programs is the screen size of

Page 51 - PRESS ‘N’ to abort

Publication 2707-PM002B-EN-PDesigning Microview Applications 3-3Screen Types and Data FormatsSome application screens require that you specify

Page 52 - Selections

Publication 2707-PM002B-EN-P3-4 Designing Microview ApplicationsData ScalingData entered by an operator can be scaled from engineering units su

Page 53 - Coded Decimal)

Publication 2707-PM002B-EN-PDesigning Microview Applications 3-5Scaling FormulasThe scaling formula for a MicroView display value is:The scalin

Page 54

Publication 2707-PM002B-EN-P3-6 Designing Microview ApplicationsApplication ExampleThe following example shows typical menus and screens of a M

Page 55

Publication 2707-PM002B-EN-PDesigning Microview Applications 3-7Description of Example ApplicationPump/Tank LevelsWhen Pump/Tank Levels is sele

Page 56

Publication 2707-PM002B-EN-P3-8 Designing Microview ApplicationsDesigning an ApplicationUse the application design worksheets to layout a logic

Page 57 - Creating Data Entry Screens

Publication 2707-PM002B-EN-PDesigning Microview Applications 3-9Recommended sequence for designing an application1. On paper, design all the op

Page 58 - Data Entry Screen Builder

i Publication 2707-PM002B-EN-PTable of ContentsTable of Contents Chapter 1Using this ManualObjectives. . . . . . . . . . . . . . . . . . . . . . . . .

Page 59 - Creating a Data Entry

Publication 2707-PM002B-EN-P3-10 Designing Microview Applications

Page 60 - Position

1 Publication 2707-PM002B-EN-PChapter 4Creating or Editing an Application FileChapter ObjectivesThis chapter describes how to open, edit and save an a

Page 61 - Data Entry Register

Publication 2707-PM002B-EN-P4-2 Creating or Editing an Application FileCreating / Editing ApplicationsTo create or edit an application:1. Selec

Page 62 - Data Entry Register Format

Publication 2707-PM002B-EN-PCreating or Editing an Application File 4-3The Edit File - Option Selection menu is displayed.3. Access the followi

Page 63

Publication 2707-PM002B-EN-P4-4 Creating or Editing an Application FileNote: If the same file name currently exists, you are prompted if you w

Page 64

1 Publication 2711-PM002B-EN-PChapter 5Using Screen BuilderChapter ObjectivesThis chapter describes how to use the Screen Builder to create or edit ap

Page 65 - Creating Security Screens

Publication 2711-PM002B-EN-P5-2 Using Screen BuilderAccessing Screen TypesTo access Screen Builder screens:1. Select Screen Builder from the Ed

Page 66 - Security Screen Builder

Publication 2711-PM002B-EN-PUsing Screen Builder 5-33. Press [F8] on any screen to access the other screen types. You are prompted for a scree

Page 67 - Creating a Security Screen

Publication 2711-PM002B-EN-P5-4 Using Screen BuilderEditing Screen DisplaysWhen you are editing screen text, the following editing operations a

Page 68

Publication 2711-PM002B-EN-PUsing Screen Builder 5-5Copying ScreensUse the copy function [F4] to save time when creating similar screens. Both

Page 69 - Creating Recipe Screens

Publication 2707-PM002B-EN-PTable of Contents iiChapter 5Using Screen BuilderChapter Objectives . . . . . . . . . . . . . . . . . . . . . . . .

Page 70 - Recipe Screen Builder

Publication 2711-PM002B-EN-P5-6 Using Screen Builder4. Enter the screen number and press [Return].The screen is copied.5. Edit the copied scree

Page 71 - Creating a Recipe Screen

Publication 2711-PM002B-EN-PUsing Screen Builder 5-7Clearing ScreensUse the [F7] Clear Screen function to clear all or part of the currently di

Page 72

Publication 2711-PM002B-EN-P5-8 Using Screen BuilderExiting Screen BuilderYou can exit Screen Builder at any time during the design of an appli

Page 73

1 Publication 2707-PM002B-EN-PChapter 6Creating Menu and Sub-Menu ScreensChapter ObjectivesThis chapter describes how to create the main menu and sub–

Page 74 - Screen Linking Guidelines

Publication 2707-PM002B-EN-P6-2 Creating Menu and Sub-Menu ScreensBuilding a MenuWhen you build a menu, you are directing the operator to more

Page 75 - Function Keys

Publication 2707-PM002B-EN-PCreating Menu and Sub-Menu Screens 6-3Main Menu and Sub-Menu Screen BuilderThe screen for creating the main menu an

Page 76 - Linking a Menu

Publication 2707-PM002B-EN-P6-4 Creating Menu and Sub-Menu ScreensCreating a Menu ScreenTo create a menu screen:1. Select Screen Builder from t

Page 77 - Linking Example

1 Publication 2707-PM002B-EN-PChapter 7Creating Data Display ScreensChapter ObjectivesThis chapter describes how to create data display screens.Data D

Page 78

Publication 2707-PM002B-EN-P7-2 Creating Data Display ScreensData Display Screen BuilderThe screen for creating data display screens has a maxi

Page 79 - Configuration Parameters

Publication 2707-PM002B-EN-PCreating Data Display Screens 7-3Creating a Display ScreenThe display register data field may be inserted anywhere

Page 80 - Accessing Configuration

Publication 2707-PM002B-EN-PTable of Contents iiiChapter 10Creating Recipe ScreensChapter Objectives . . . . . . . . . . . . . . . . . . . . .

Page 81 - Update Interval

Publication 2707-PM002B-EN-P7-4 Creating Data Display Screens4. Enter the screen text to the point where you want the data display field to be

Page 82 - MicroView Advisor

Publication 2707-PM002B-EN-PCreating Data Display Screens 7-58. After entering the register data, press [Esc] to save the data and return to th

Page 83 - Advisor Operation

Publication 2707-PM002B-EN-P7-6 Creating Data Display ScreensDisplay Register Format SelectionsWhen inserting a data display field, you must pr

Page 84 - Setting Master Security

Publication 2707-PM002B-EN-PCreating Data Display Screens 7-716 Bit Signed Integer, 16 Bit Unsigned Integer, 16 Bit BCD (Binary Coded Decimal)T

Page 85 - Special Security Screen

Publication 2707-PM002B-EN-P7-8 Creating Data Display Screens16 Bit HEX (Hexadecimal)The screen for a 16 Bit Hex format is shown below. Format

Page 86

Publication 2707-PM002B-EN-PCreating Data Display Screens 7-9ASCIIThe screen for an ASCII format is shown below:Each data display can only be 1

Page 87 - Parameters

Publication 2707-PM002B-EN-P7-10 Creating Data Display Screens

Page 88 - Com Port Setup

1 Publication 2707-PM002B-EN-PChapter 8Creating Data Entry ScreensChapter ObjectivesThis chapter describes how to create data entry screensData entry

Page 89

Publication 2707-PM002B-EN-P8-2 Creating Data Entry ScreensData Entry Screen BuilderThe screen for creating data entry screens has a display si

Page 90 - Advisor Update Rate

Publication 2707-PM002B-EN-PCreating Data Entry Screens 8-3Creating a Data Entry ScreenThe entry register data field may be inserted anywhere o

Page 91 - Function Key Options

Publication 2707-PM002B-EN-PTable of Contents ivChapter 14Transferring / Printing Application FilesChapter Objectives . . . . . . . . . . . . .

Page 92 - Continue

Publication 2707-PM002B-EN-P8-4 Creating Data Entry Screens4. Create all of the screen text and, if used, a data display field. Refer to Chapt

Page 93 - Bit Write Mode

Publication 2707-PM002B-EN-PCreating Data Entry Screens 8-57. Select a register type.You are prompted for data specific to the selected registe

Page 94 - Function Key Builder

Publication 2707-PM002B-EN-P8-6 Creating Data Entry ScreensData Entry Register Format SelectionsWhen inserting a data entry field, you must pro

Page 95 - Linking Screens to Function

Publication 2707-PM002B-EN-PCreating Data Entry Screens 8-716 Bit Signed Integer,16 Bit Unsigned Integer,16 Bit BCD Binary Coded Decimal)The sc

Page 96 - Functions

Publication 2707-PM002B-EN-P8-8 Creating Data Entry Screens

Page 97 - Register Assignments

1 Publication 2707-PM002B-EN-PChapter 9Creating Security ScreensChapter ObjectivesThis chapter describes how to create security screens.Security Scree

Page 98

Publication 2707-PM002B-EN-P9-2 Creating Security ScreensSecurity Screen BuilderThis is the Security Screen Builder display.Security Screen Bui

Page 99

Publication 2707-PM002B-EN-PCreating Security Screens 9-3Creating a Security ScreenYou can specify up to three separate codes for each Security

Page 100 - Application

Publication 2707-PM002B-EN-P9-4 Creating Security ScreensIf you are editing a screen with a previously defined security code(s), you must press

Page 101 - Publication 2707-PM002B-EN-P

1 Publication 2707-PM002B-EN-PChapter 10Creating Recipe ScreensChapter ObjectivesThis chapter describes how to create recipe screens.Recipe Screens al

Page 102

1 Publication 2707-PM002B-EN-PChapter 1Using this ManualObjectivesRead this chapter to familiarize yourself with the rest of the manual. You will lea

Page 103 - Uploading an Application

Publication 2707-PM002B-EN-P10-2 Creating Recipe ScreensRecipe Screen BuilderThe screen for creating recipe screens is shown below:Recipe Scree

Page 104

Publication 2707-PM002B-EN-PCreating Recipe Screens 10-3Creating a Recipe ScreenTo create a recipe screen:1. Select Screen Builder from the Edi

Page 105

Publication 2707-PM002B-EN-P10-4 Creating Recipe Screens You are prompted for a register type.5. Select a register type and press [Return]. You

Page 106 - Printing Application Files

1 Publication 2707-PM002B-EN-PChapter 11Linking Menu and Application ScreensChapter ObjectivesThis chapter describes how to link the application scree

Page 107

Publication 2707-PM002B-EN-P11-2 Linking Menu and Application ScreensLinking Menu ScreensMenu and sub-menu links provide one way links with up

Page 108

Publication 2707-PM002B-EN-PLinking Menu and Application Screens 11-3Application Screen Linking Function KeysWhen you press [F3] MAP Screen on

Page 109 - Operating System

Publication 2707-PM002B-EN-P11-4 Linking Menu and Application ScreensMenu and Sub Menu Linkage DisplayWhen you press [F3] MAP Screen on a main

Page 110

Publication 2707-PM002B-EN-PLinking Menu and Application Screens 11-53. Enter the screen # you want linked to numeric entry key [1] and press [

Page 111

Publication 2707-PM002B-EN-P11-6 Linking Menu and Application Screens2. Press [F3] to select the MAP Screen function.The current screen links

Page 112

1 Publication 2707-PM002B-EN-PChapter 12Entering MicroView Configuration DataChapter ObjectivesThis chapter describes how to set the configuration par

Page 113 - ASCII Character Set

Publication 2707-PM002B-EN-P 1-2 Using this ManualIntended AudienceThe MicroView Programming Software does not require special programming know

Page 114

Publication 2707-PM002B-EN-P12-2 Entering MicroView Configuration DataAccessing Configuration DataThe following shows how to access MicroView c

Page 115

Publication 2707-PM002B-EN-PEntering MicroView Configuration Data 12-3Update IntervalThe update interval specifies the display update rate of t

Page 116

Publication 2707-PM002B-EN-P12-4 Entering MicroView Configuration DataMicroView AdvisorThe Advisor function allows screen changes to be made by

Page 117 - Appendix

Publication 2707-PM002B-EN-PEntering MicroView Configuration Data 12-5Advisor OperationThe following shows how the Advisor function operates.

Page 118

Publication 2707-PM002B-EN-P12-6 Entering MicroView Configuration DataSetting Master Security CodeWhen you select Master Code from the Configur

Page 119

Publication 2707-PM002B-EN-PEntering MicroView Configuration Data 12-7Special Security ScreenThe special security screen restricts access to th

Page 120 - MicroView Screen Worksheet

Publication 2707-PM002B-EN-P12-8 Entering MicroView Configuration DataTo edit the screen text:You can edit the screen text from the second secu

Page 121

Publication 2707-PM002B-EN-PEntering MicroView Configuration Data 12-9MicroLogix Hardware ParametersWhen using DF1 protocols, you must specify

Page 122

Publication 2707-PM002B-EN-P12-10 Entering MicroView Configuration DataCom Port SetupSelecting Com Port Setup displays: The Communications Port

Page 123 - MicroLogix Mnemonics in DPS

Publication 2707-PM002B-EN-PEntering MicroView Configuration Data 12-11If you wish to change the baud rate of the MicroView, press [Return] to

Page 124

Publication 2707-PM002B-EN-P Using this Manual 1-3ConventionsThis manual uses the following conventions:• Keys that you press on your personal

Page 125 - MicroLogix Data Formats

Publication 2707-PM002B-EN-P12-12 Entering MicroView Configuration DataAdvisor Update RateSelecting Advisor Update Rate from the PLC Hardware P

Page 126 - 16 Bit Unsigned Integer

1 Publication 2707-PM002B-EN-PChapter 13MicroView Function Key BuilderChapter ObjectivesThis chapter describes how to use the Function Key Builder to

Page 127 - 16 Bit HEX (Hexadecimal)

Publication 2707-PM002B-EN-P13-2 MicroView Function Key BuilderAuto ReturnAuto return function keys return to the initial display after the lin

Page 128

Publication 2707-PM002B-EN-PMicroView Function Key Builder 13-3Bit Write ModeThe function keys of the MicroView can also set or clear bits in t

Page 129

Publication 2707-PM002B-EN-P13-4 MicroView Function Key BuilderFunction Key BuilderThe screen for assigning MicroView function key options is s

Page 130 - 2 Index

Publication 2707-PM002B-EN-PMicroView Function Key Builder 13-5Linking Screens to Function KeysYou can link function keys [F1] and [F2] to indi

Page 131 - Index 3

Publication 2707-PM002B-EN-P13-6 MicroView Function Key BuilderAssigning Bit Write FunctionsTo assign bit write mode functions:1. Open the Func

Page 132 - 4 Index

Publication 2707-PM002B-EN-PMicroView Function Key Builder 13-74. Enter [1] or [0] and press [Return]. Press [Esc] when done.The function key r

Page 133

Publication 2707-PM002B-EN-P13-8 MicroView Function Key Builder

Page 134 - Back Cover

1 Publication 2707-PM002B-EN-PChapter 14Transferring / Printing Application FilesChapter ObjectivesThis chapter describes how to transfer application

Commentaires sur ces manuels

Pas de commentaire