Rockwell-automation 20-COMM-E PowerFlex EtherNet/IP Adapter Manuel d'utilisateur Page 256

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 296
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 255
C-22 EtherNet/IP Objects
20-COMM-E EtherNet/IP Adapter User Manual
Publication 20COMM-UM010G-EN-P
DPI Fault Object
Class Code
Products such as PowerFlex drives use this object for faults. Adapters use
this object for events.
Services
Instances
The number of instances depends on the maximum number of faults or
events supported in the queue. The maximum number of faults/events can
be read in Instance 0, Attribute 2.
Class Attributes
Hexadecimal Decimal
0x97 151
Service Code Implemented for: Service Name
Class Instance
0x0E Yes Yes Get_Attribute_Single
0x10 Yes Yes Set_Attribute_Single
Instances (Hex.) (Dec.) Device Example Description
0x0000…0x3FFF 0…16383 Host 0 Class Attributes (Drive)
0x4000…0x43FF 16384…17407 Adapter 1 Most Recent Drive Fault
0x4400…0x47FF 17408…18431 DPI Port 1 2 Second Most Recent Drive Fault
0x4800…0x4BFF 18432…19455 DPI Port 2
0x4C00…0x4FFF 19456…20479 DPI Port 3 16384 Class Attributes (Adapter)
0x5000…0x53FF 20480…21503 DPI Port 4 16385 Most Recent Adapter Event
0x5400…0x57FF 21504…22527 DPI Port 5
0x5800…0x5BFF 22528…23551 DPI Port 6
0x5C00…0x5FFF
(1)
(1)
These instances are supported only when the adapter is used with a PowerFlex 750-Series drive.
23552…24575 DPI Port 7
0x6000…0x63FF
(1)
24576…25599 DPI Port 8
0x6400…0x67FF
(1)
25600…26623 DPI Port 9
0x6800…0x6BFF
(1)
26624…27647 DPI Port 10
0x6C00…0x6FFF
(1)
27648…28671 DPI Port 11
0x7000…0x73FF
(1)
28672…29695 DPI Port 12
0x7400…0x77FF
(1)
29696…30719 DPI Port 13
0x7800…0x7BFF
(1)
30720…31743 DPI Port 14
Attribute ID Access Rule Name Data Type Description
1 Get Class Revision WORD Revision of object
2 Get Number of Instances WORD Maximum number of faults/events that the
device can record in its queue
3 Set Fault Command Write BYTE 0 = No Operation
1 = Clear Fault/Event
2 = Clear Fault/Event Queue
3 = Reset Device
4 Get Fault Trip Instance Read WORD Fault that tripped the device. For adapters,
this value is always 1 when faulted.