7-8 Troubleshooting
20-COMM-E EtherNet/IP Adapter User Manual
Publication 20COMM-UM010G-EN-P
11 Dup Port Flt Another peripheral with the same port number is already in use.
12 Type 0 Login The adapter has logged in for Type 0 control.
13 Type 0 Time Flt The adapter has not received a Type 0 status message within the specified time.
14 DL Login The adapter has logged into a Datalink.
15 DL Reject Flt The drive rejected an attempt to log in to a Datalink because the Datalink is not supported or is used by another
peripheral.
16 DL Time Flt The adapter has not received a Datalink message within the specified time.
17 Reserved Not used.
18 Control Disabled The adapter has sent a ‘Soft Control Disable’ command to the drive.
19 Control Enabled The adapter has sent a ‘Soft Control Enable’ command to the drive.
20 Message Timeout A Client-Server message sent by the adapter was not completed within 1 sec.
21 Flt Cfg Error One of the Flt Cfg xx parameters is set to a value greater than 65535 and the drive requires a 16-bit value.
22 App Updated Startup sequence detected new application firmware.
23 EN Comm Flt The adapter detected a communications fault on the network.
24 EN Sent Reset The adapter received a reset from the network.
25 EN Close Flt An I/O connection from the network to the adapter was closed.
26 EN Idle Flt The adapter is receiving ‘idle’ packets from the network.
27 EN Open An I/O connection from the network to the adapter has been opened.
28 EN Timeout Flt An I/O connection from the network to the adapter has timed out.
29 PCCC IO Close The device sending PCCC Control messages to the adapter has set the PCCC Control Timeout to zero.
30 PCCC IO Open The adapter has begun receiving PCCC control messages (the PCCC Control Timeout was previously set to a
non-zero value).
31 PCCC IO Time Flt The adapter has not received a PCCC Control message for longer than the PCCC Control Timeout.
32 Watchdog T/O Flt The software detects a failure.
33 EEPROM Init Startup sequence detected a blank EEPROM map revision.
34 Normal Startup The adapter successfully started up.
35 Manual Reset The adapter was reset by changing its Reset Module parameter.
36 EN Link Down The Ethernet link was removed from the adapter.
37 EN Link Up An Ethernet link is available for the adapter.
38 BOOTP Response The adapter received a response to its BOOTP request.
39 Dup IP Addr The adapter uses the same IP address as another device on the network.
40 Peer IO Open The adapter received the first Peer I/O message.
41 Peer IO Time Flt The adapter has not received a Peer I/O message for longer than the Peer I/O Timeout.
42 Email Failed The adapter encountered an error attempting to send a requested e-mail message.
43 Msg Ctrl Open The timeout attribute in either the CIP Register or Assembly object was written with a non-zero value, allowing
control messages to be sent to the adapter.
44 Msg Ctrl Close The timeout attribute in either the CIP Register or Assembly object was written with a zero value, disallowing
control messages to be sent to the adapter.
45 Msg Ctrl Timeout The timeout attribute in either the CIP Register or Assembly object elapsed between accesses of those objects.
46 OPT Open The adapter began exchanging I/O data with the I/O option of the DPI External Comms Kit.
47 OPT Close The adapter forced a fault condition on the I/O option of the DPI External Comms Kit.
48 OPT Timeout Communication between the adapter and I/O option of the DPI External Comms Kit was disrupted.
Table 7.B Adapter Events (Continued)
Code Event Description