1000
UDC Test Switch Inputs Register (Continued)
Bit: 2
Hex Value: 0004H
Sug. Var. Name:
SWIT_DN@
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Description: The Switch Down Input bit is on when the switch is in the down position.
Bit: 8
Hex Value:
01
00H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED: OS OK on the UDC module
Description: Status of the Operating System OK LED on the UDC module (0 = Off; 1 = On).
Bit: 9
Hex Value: 0200H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED: COMM A OK on the UDC module
Description: Status of the COMM A OK LED on the UDC module (0 = Off; 1 = On).
Bit:
10
Hex Value: 0400H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED: DRV A FLT on the UDC module
Description: Status of the Drive A Fault LED on the UDC module (0 = Off; 1 = On).
Bit:
11
Hex Value: 0800H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED: COMM B OK on the UDC module
Description: Status of the COMM B OK LED on the UDC module (0 = Off; 1 = On).
Bit: 12
Hex Value: 1
000H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED: DRV B FLT on the UDC module
Description: Status of the Drive B Fault LED on the UDC module (0 = Off;
1
= On).
3-41