PMI
A/B Format Error Count Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Description: This register contains the number of messages with format errors received by the Drive
A and Drive B
PMls.
88/1
088
UDC Module Potts A/B Fiber-Optic Link Status Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Description: This register indicates the current operating state of fiber-optic links A and B. The lower
byte (bits O-7) indicates the actual link status while the upper byte (bits 8-15) shows whether the
communication taking place is synchronized or not.
l
If the lower byte is equal to (xx01 H), the UDC module is waiting for a request from the PMI for an
operating system.
l
If the lower byte is equal to (xx02H), the UDC module is downloading an operating system to the
PMI.
l If the lower byte is equal to (xx03H), the UDC module and the PMI are exchanging data.
l
If the lower byte is equal to
(xx06H),
the external loopback test is being conducted on the fiber-optic
link.
l
If the upper byte is equal to (01xxH), the communication between the UDC module and the PMI is
synchronized.
l
If the upper byte is equal to (02xxH), the communication between the UDC module and the PMI is
unsynchronized.
89/1 089
UDC Module Ports A/B Transmitted Message Count Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Description: This register contains the number of messages transmitted by the UDC module on Port
A and Port B.