Publication 2711P-QS001A-EN-P - October 2007 137
Measure and Improve Runtime Application Performance Chapter 9
Run the Tag Converter Wizard
Now that you have completed the pre-conversion process, you are
ready to run the tag converter wizard. The executable file is named
TCW.exe.
1. Double-click the TCW.exe
utility.
2. Select a Conversion Type.
a. Select RIO Tag
Optimization if your
application uses RIO
communication.
b. Select HMI to Direct Tag
if your application uses
DH+ or ControlNet
communication.
3. Click the ... button next to
the Exported Tag Database
field and load the exported
tag database.
The file is located in the
directory specified in step 6
on page 132.
4. Click the Add button next to
Exported alarms/displays.
Vue de la page 136