54 Rockwell Automation Publication 842E-UM001A-EN-P May 2012
Appendix B RSLogix 5000 sample code
Set up the Configuration tab as follows.
1. Set Parameter Scaling to Enable.
2. Set Counts per Revolution to 200.
3. Total Measuring Range will be 51,200.
4. Position the slide/encoder to a known start position.
5. Set the preset value. The preset value will be retained by the encoder
through a machine cycle.
Setting up your project
1. Create a new program file. Select the processor revision and name the
project file. In this example the CompactLogix 1769-L35E V20 was used.