3Ć4






0 1
2
3
IĆOUT
Common
(no label)
4Ć20mA+ output
common
(shield; no connection)*
1 4
5
6
IĆOUT
Common
(no label)
4Ć20mA+ output
common
(shield; no connection)*
2 7
8
9
IĆOUT
Common
(no label)
4Ć20mA+ output
common
(shield; no connection)*
3 10
11
12
IĆOUT
Common
(no label)
4Ć20mA+ output
common
(shield; no connection)*
*This terminal makes no electrical connection to the Analog Rail printed circuit
board.
Step 10. For each of the four output channels, connect a shield
wire from the external hardware to the third terminal
(terminals 3, 6, 9, and 12, respectively). The shield wire at
the external hardware end of the cable should be
connected to the source reference point. See figure 3.2.