Rockwell-automation 61C365 4 Output 4-20mA Analog Rail Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Rockwell-automation 61C365 4 Output 4-20mA Analog Rail. Rockwell Automation 61C365 4 Output 4-20mA Analog Rail User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 -   

        

Page 2

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Page 3 - Table of Contents

2.0 MECHANICAL/ELECTRICALDESCRIPTION            2.1 Mech

Page 4 - 

2Ć2GNDFuse Type250V MDQ24 VDC:Use 0.75A120 VAC:Use 0.25ADC-DC+L2L124VDC120VACInput PowerAnalog OutputsModeInputAnalog Rail61C3654 to 20 mA OUTPUTPWRO

Page 5 -   

2Ć3The faceplate of the module contains three electrical connectorslabeled Input", Analog Outputs", and Input Power" (reading top to

Page 6

2Ć4DACRFB+10.000 VIĆOUT104.1670.416 2.083 VI-OUT-Figure 2.2 Ć Typical Output CircuitThe Analog Rail module is factory calibrated and requires nooffs

Page 7 -  

,3.0 INSTALLATION% %&! %$% !) &!  %&   $" &  ! !' !& &&  ! %

Page 8

3Ć2  Use the following procedure to install the Analog Rail module.Step 1. Using the mounting dimensions shown in figure 3.1,pre

Page 9

3Ć3Step 2. If the power supply you are using is 24 VDC, replace thefactoryĆinstalled .25A fuse with the .75A fuse that came inthe shipping box with th

Page 10

3Ć40 123IĆOUTCommon(no label)4Ć20mA+ outputcommon(shield; no connection)*1 456IĆOUTCommon(no label)4Ć20mA+ out

Page 11 - DESCRIPTION

3Ć5Channel 0Channel 1Channel 2Channel 3-++-LoadSourceIĆOutCommon123-++-LoadSourceIĆOutCommon456IĆOutCommon789IĆOutCommon101112-++-LoadSource-++-Lo

Page 12 - 4 to 20 mA OUTPUT

AutoMax, AutoMate, and Reliance are registered trademarks of Reliance ElectricąąCompany or its subsidiaries.Belden is a registered trademark of Be

Page 13 - 2.2 Electrical Description

3Ć6Step 16. Verify that the hardware has been installed correctly.Before testing, insure that the external hardware will notrespond to output signals

Page 14

3Ć7Remove the .25A fuse from the fuse holder and replace itwith the .75A fuse. ReĆinsert the fuse holder into themodule. Turn the screwdriver clockwis

Page 15 - 3.0 INSTALLATION

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Page 16 -   

4Ć14.0 PROGRAMMINGThis section describes how the data is organized in the module andprovides examples of how the module is accessed by applicationprog

Page 17

4Ć2Analog Rail Module with AutoMate 20(Local Head Mode or Rail Mode)AutoMate 20 registers reserved for port configuration:2734 Port 0 of AutoMate 2027

Page 18

4Ć3Analog Rail Module Connected Directly to AutoMate 30 or 40(Local Head Mode or Rail Mode)The following sample configuration shows two Analog Rail mo

Page 19

4Ć4Analog Rail Module Connected to AutoMate 30 or 40 Through a Local I/O Head(Rail Mode Only)The following sample configuration shows two Analog Rail

Page 20 - 3.3 Module Replacement

4Ć5Analog Rail Module with AutoMate Local I/O Processor (Local Head Mode Only)The following sample configuration shows three Analog Rail modules conne

Page 21

4Ć6Analog Rail Module with AutoMate Remote I/O Head (Local Head Mode Only)The following sample configuration shows one Analog Rail module connected to

Page 22

4Ć74.1.2 AutoMate Programming in Rail ModeIn Rail mode, the Analog Rail module is imaged in one I/O register ofthe processor. Data from one of the fou

Page 23 - 4.0 PROGRAMMING

ITable of Contents1.0 Introduction 1Ć1...1.1 Additional Information 1Ć1...

Page 24

4Ć84.1.3 AutoMate Programming in Local Head ModeIn Local Head mode, the module is imaged in four I/O registers ofthe processor. Data from all four cha

Page 25

4Ć9AOUT Instruction BlockThe example below shows an AOUT block for an Analog Rail module connectedto port 2 of a local I/O head, which in turn is conn

Page 26

4Ć10For DCS 5000 or AutoMax Version 2.1 or earlier, use the RIODEFstatement to define each channel on the Analog Rail module as aseparate register. Us

Page 27

5Ć15.0 DIAGNOSTICS ANDTROUBLESHOOTINGDANGERTHE REMAINING STEPS ARE MADE WITH POWER ON. EXERCISE EXTREMECAUTION BECAUSE HAZARDOUS VOLTAGE EXISTS. FAILU

Page 28

5Ć2DANGERDO NOT TOUCH THE CONNECTORS ON THE FACEPLATE IF THERE IS POWERON THE WIRES ATTACHED TO THE PLUG CONNECTOR SCREW TERMINALS.ALWAYS TURN OFF POW

Page 29

5Ć35.2 The COM OK" LED is OffProblem: The COM OK" LED on the faceplate is off. This LEDsignifies whether there is communication between th

Page 30

5Ć4Step 1. Verify that the application program(s) is correct. Check tosee that the program is referencing the correct registers(AutoMate) or symbolic

Page 31

AĆ1Appendix ATechnical SpecificationsAmbient Conditions Storage temperature: -40Cto85C-40Fto185F Operating temperature (at the module): 0Cto60

Page 32

AĆ2   Operating range: 4Ć20mA (shortĆcircuit protected) Number of channels: 4 (singleĆended) Number of commons: 1

Page 33 - TROUBLESHOOTING

BĆ1  CIRCUITRY4-20mA OUT4-20mA OUT4-20mA OUT4-20mA OUTISOLATIONBOUNDARYMAINCONTROLCIRCUITRYRESETAMPAMPAMPAMPVREFVREFVREFVREFVREFP

Page 34

II Technical Specifications AĆ1... Block Diagram BĆ1...

Page 35 - 5.3 Incorrect Data

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Page 36

CĆ1   The following AutoMate program sequences can be used to interface to anAutoMate Processor that does not support th

Page 37 - Appendix A

CĆ2 If counter = 2, then move the data in register 42 to register 0.44.17[Ă/Ă]Ă45.02(ăă)EN MOVE ENLENGTH: 1SRC: 42DEST: 044.16[Ă/Ă

Page 38 -  

CĆ3 Increment counter 0, 1, 2, 3 and then back to 0.Ă45.10(ăă)EN ADD ENLENGTH: 1SRC: 44SCR 2: K1DEST: 44Ă45.11(ăă)EN ADD ENLENGTH:

Page 39 -  

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Page 40

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Page 41 -  

For additional information1 Allen-Bradley DriveMayfield Heights, Ohio 44124 USATel: (800) 241-2886 or (440) 646-3599http://www.reliance.com/automaxCop

Page 42 -  

III  Figure 1.1 Ć Analog Rail Module Hardware Configuration 1Ć3...Figure 2.1 Ć Analog Rail Module Faceplate 2Ć2...

Page 43

fafadfdfdasfdsfdsdsdfdsfdsfdsfsdfdsaafdfdsfdsfdfdsfdsfsadfdaasfdfaddfdd

Page 44

1Ć1 The products described in this instruction manual are manufacturedby Reliance Electric Industrial Company.The 4 Output 4Ć20 mA Anal

Page 45

1Ć2 JĆ3141 AutoMate 40 CONTROL PROCESSOR INSTRUCTIONMANUAL JĆ3150 AutoMate 30/40 SOFTWARE REFERENCE MANUAL JĆ3649 DCS 5000/AutoMax CONFIGURATION TA

Page 46 - 1 Allen-Bradley Drive

1Ć3The Analog Rail module can be configured with the hardware(purchased separately) listed in figure 1.1.  DCS 5000/AutoMaxRemot

Commentaires sur ces manuels

Pas de commentaire