Rockwell-automation 25-COMM-E2P PowerFlex 25-COMM-E2P Dual-Port EtherN Manuel d'utilisateur Page 131

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 172
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 130
Rockwell Automation Publication 520COM-UM003A-EN-E - June 2013 131
EtherNet/IP Objects Appendix C
Instance Attributes
Attribute ID Access Rule Name Data Type Description
1 Get Vendor ID UINT 1 = Allen-Bradley
2 Get Device Type UINT 151
3 Get Product Code UINT Number identifying product name and rating
4 Get Revision:
Major
Minor
STRUCT of:
USINT
USINT
Value varies
Value varies
5 Get Status UINT Bit 0 = Owned
Bit 8 = Minor recoverable fault
Bit 10 = Major recoverable fault
6 Get Serial Number UDINT Unique 32-bit number
7 Get Product Name SHORT_STRING Product name
9GetConfiguration
Consistency
Value
UNIT Current Parameter NVS CRC value
Vue de la page 130
1 2 ... 126 127 128 129 130 131 132 133 134 135 136 ... 171 172