Installation Instructions
Multi-Device Interface Option Board for
PowerFlex® 700S Drives
What This Kit Contains
Verify that your kit contains the items listed in the following table. If your
kit does not contain the correct items, contact your Rockwell Automation
sales representative.
!
ATTENTION: To avoid an electric shock hazard, ensure that
all power to the drive has been removed before performing the
following.
!
ATTENTION: To avoid an electric shock hazard, verify that
the voltage on the bus capacitors has discharged before
performing any work on the drive. Measure the DC bus voltage
at the DC+ & DC- terminals. The voltage must be zero.
!
ATTENTION: HOT surfaces can cause severe burns. Do not
touch the heatsink surface during operation of the drive. After
disconnecting power allow time for cooling.
!
ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing or
repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with
static control procedures, reference A-B publication 8000-4.5.2,
“Guarding Against Electrostatic Damage” or any other
applicable ESD protection handbook.
!
ATTENTION: Hazard of permanent eye damage exists when
using optical transmission equipment. This product emits intense
light and invisible radiation. Do not look into SynchLink
fiber-optic ports or SynchLink fiber-optic cable connectors.
!
ATTENTION: The sheet metal cover and mounting screws on
the ASIC Board located on the power structure are energized at
(-) DC bus potential high voltage. Risk of electrical shock,
injury, or death exists if someone comes in contact with the
assembly.
Quantity: Description
1 MDI Option circuit board
2 “Stacker” connectors
1Screw
3 Stand-offs
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - PowerFlex® 700S Drives

Installation InstructionsMulti-Device Interface Option Board for PowerFlex® 700S Drives What This Kit ContainsVerify that your kit contains the items

Page 2 - Step 1: Remove Power

10 Multi-Device Interface Option Board for PowerFlex® 700S Drives Step 8: Wire the MDI Option BoardTerminal block P1 contains connection points for a

Page 3 - Step 2: Remove the Drive

Multi-Device Interface Option Board for PowerFlex® 700S Drives 11 Recommended CablesIf you are using this motor and feedback device: Use this cable: S

Page 4 - Frame 10 - 13 Size Drives

12 Multi-Device Interface Option Board for PowerFlex® 700S Drives Figure 2 Rotary Encoder connections for MPL-A5xx and MPL-Bxxx motors or 1326AB-BXX

Page 5 - Phase I Drive (if necessary)

Multi-Device Interface Option Board for PowerFlex® 700S Drives 13 Figure 5 Rotary Encoder connections for MPL-A3xx - MPL-A45xx and all MPG series mo

Page 6 - II Control Cassette Covers

14 Multi-Device Interface Option Board for PowerFlex® 700S Drives Figure 8 Rotary Encoder connections with Stegmann shielded twisted-pair cable and

Page 7 - Existing MDI Option Board

Multi-Device Interface Option Board for PowerFlex® 700S Drives 15 Step 9: Install the Phase II Control Cassette CoversIn order to install the Phase II

Page 8 - Step 6: Install the New MDI

16 Multi-Device Interface Option Board for PowerFlex® 700S Drives Install the Phase II Control Cassette Frame 9 - 13 Size Drives Task DescriptionSlide

Page 9 - (if removed in Step 3)

Multi-Device Interface Option Board for PowerFlex® 700S Drives 17 Step 10: Document the ChangeDocument the installation of the MDI option board on the

Page 10 - Option Board

18 Multi-Device Interface Option Board for PowerFlex® 700S Drives Step 11: Install the Drive Cover(s)Phase I Drives Frames 1 - 6 The procedure for ins

Page 11 - Recommended Cables

Multi-Device Interface Option Board for PowerFlex® 700S Drives 19 Supported Linear SensorsImportant:Only one Linear Sensor can be installed at a time.

Page 12 - Connection Examples

2 Multi-Device Interface Option Board for PowerFlex® 700S Drives Tools That You Need• Phillips® screwdriver for M3 screws• POZIDRIV® screwdriver for M

Page 13

Publication 20D-IN004B-EN-P - May 2008 P/N 314350-P01Supersedes 20D-IN004A-EN-P – August 2005 Copyright © 2008 Rockwell Automation. All rights reserv

Page 14

Multi-Device Interface Option Board for PowerFlex® 700S Drives 3 Step 2: Remove the Drive Cover(s) Frame 1 - 6 Size DrivesEsc7 8 94 5 61 2 3.0 +/-SelJ

Page 15 - Control Cassette Covers

4 Multi-Device Interface Option Board for PowerFlex® 700S Drives Frame 9 Size DrivesFrame 10 - 13 Size DrivesOpen the door of the drive enclosure cont

Page 16 - Frame 1 - 6 Size Drives

Multi-Device Interface Option Board for PowerFlex® 700S Drives 5 Step 3: Remove the Control Assembly from Phase I Drive (if necessary)This step is nec

Page 17 - Step 10: Document the

6 Multi-Device Interface Option Board for PowerFlex® 700S Drives Step 4: Remove the Phase II Control Cassette CoversIt is necessary to remove the cass

Page 18 - Specifications

Multi-Device Interface Option Board for PowerFlex® 700S Drives 7 Remove the Phase II Cassette Covers (All Drive Sizes) Step 5: Remove the Existing MDI

Page 19 - Supported Rotary Encoders

8 Multi-Device Interface Option Board for PowerFlex® 700S Drives Step 6: Install the New MDI Option BoardPhase I DrivesImportant:Do not use a screwdri

Page 20

Multi-Device Interface Option Board for PowerFlex® 700S Drives 9 Phase II DrivesImportant:Do not use a screwdriver to pry the P1 terminal block from t