Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Manuel d'utilisateur Page 129

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 176
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 128
Publication 2098-RM003A-EN-P October 2001
Command Reference 2-113
Position Error
Positive Peak Position Error
Negative Peak Position Error
Velocity Command
Format: :aa081fddddddddcc<cr>
Parameter
Code:
0x081
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddddddd Position error, in units of counts.
Format: :aa082fddddddddcc<cr>
Parameter
Code:
0x082
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddddddd Peak positive position error, in units of counts.
Format: :aa083fddddddddcc<cr>
Parameter
Code:
0x083
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddddddd Peak negative position error, in units of counts.
Format: :aa084fddddddddcc<cr>
Parameter
Code:
0x084
Valid Function
Codes:
0x0 = Read Working Value
Valid Exception
Codes:
0x08 = Invalid Function Code
Data Fields: dddddddd Velocity command, in units of counts/second.
Vue de la page 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 175 176

Commentaires sur ces manuels

Pas de commentaire