Rockwell-automation 1798-OE2 FlexArmor Analog Output Module Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Rockwell-automation 1798-OE2 FlexArmor Analog Output Module. Rockwell Automation 1798-OE2 FlexArmor Analog Output Module User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Publication 1798-IN009A-EN-P - April 2002
Installation Instructions
FlexArmor Analog Output Module
Catalog Number 1798-OE2
The FlexArmor I/O module (Cat. No. 1798-OE2) mounts in a
FlexArmor Baseplate. Use compatible sealed cordsets to connect all
field side wiring. All cordsets must be shielded to achieve proper
noise immunity.
The 1798-OE2 module provides connections for up to 2 single ended
non-isolated outputs. This module has two 12 mm connectors
configured for analog output. A diagnostic feature for this module
includes sensor power short-circuit detection. The outputs can be
either voltage or current.
Package Contents
Your package contains one FlexArmor 1798-OE2 module and these
installation instructions. (Note: Baseplates and other components are
ordered and shipped separately.)
43000
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - Installation Instructions

Publication 1798-IN009A-EN-P - April 2002Installation InstructionsFlexArmor Analog Output Module Catalog Number 1798-OE2The FlexArmor I/O module (Cat

Page 2 - Important User Information

2 FlexArmor Analog Output Module Publication 1798-IN009A-EN-P - April 2002Important User InformationBecause of the variety of uses for the prod

Page 3

FlexArmor Analog Output Module 3Publication 1798-IN009A-EN-P - April 2002IMPORTANTIdentifies information that is critical for successful appli

Page 4 - Related Publications

4 FlexArmor Analog Output Module Publication 1798-IN009A-EN-P - April 2002Related Publications• For DeviceNet software configuration informatio

Page 5

FlexArmor Analog Output Module 5Publication 1798-IN009A-EN-P - April 20024. Screw down the module retaining screws to ensure IP67 compliance.

Page 6 - Specifications

6 FlexArmor Analog Output Module Publication 1798-IN009A-EN-P - April 2002Troubleshooting with the IndicatorsThe following table describes the

Page 7

FlexArmor Analog Output Module 7Publication 1798-IN009A-EN-P - April 2002Specifications - 1798-OE2 Analog Output Module (continued)Dimensions(

Page 8

Publication 1798-IN009A-EN-P - April 2002 PN 957564-46 Copyright © 2002 Rockwell Automation. All rights reserved. Printed in the U.S.A.Allen-Bradley i

Commentaires sur ces manuels