Rockwell-automation 1769-IF4I CompactLogix Isolated Analog Input Modul Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Rockwell-automation 1769-IF4I CompactLogix Isolated Analog Input Modul. Rockwell Automation 1769-IF4I CompactLogix Isolated Analog Input Module User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation Instructions
CompactLogix Isolated Analog
Input Module
Catalog Number
1769-IF4I
Topic Page
Important User Information 2
North American Hazardous Location Approval 3
Module Description 5
Prevent Electrostatic Discharge 6
System Assembly 6
Mounting Expansion I/O 7
Replacing a Single Module within a System 9
Replacement Part 10
System Wiring Guidelines 10
I/O Memory Mapping 14
Specifications 18
Additional Resources 23
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Input Module

Installation InstructionsCompactLogix Isolated Analog Input ModuleCatalog Number 1769-IF4ITopic PageImportant User Information 2North American Hazardo

Page 2 - Important User Information

10 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 20117. Slide the replacement module into the open slot.8. Connect

Page 3 - Risque d’Explosion –

CompactLogix Isolated Analog Input Module 11Publication 1769-IN074C-EN-P - March 2011• Voltages on Ch+, Ch-, and Ch_iRtn for a single, isolated ch

Page 4 - Environment and Enclosure

12 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011Wiring Single-ended Sensor/Transmitter TypesWiring Mixed Tran

Page 5 - Module Description

CompactLogix Isolated Analog Input Module 13Publication 1769-IN074C-EN-P - March 2011Labeling the TerminalsA removable, write-on label is provided

Page 6 - System Assembly

14 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011You can use the bare wire or a spade lug. The terminals will

Page 7 - Mounting Expansion I/O

CompactLogix Isolated Analog Input Module 15Publication 1769-IN074C-EN-P - March 2011The bits are defined as follows:• SGN = Sign bit in two’s com

Page 8 - Panel Mounting

16 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011Configuration Data FileThe manipulation of the bits from this

Page 9 - DIN Rail Mounting

CompactLogix Isolated Analog Input Module 17Publication 1769-IN074C-EN-P - March 2011The bits are defined as follows:• EC = Enable Channel• Inpt D

Page 10 - System Wiring Guidelines

18 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011SpecificationsBit Definitions for Input Range and Input Data

Page 11 - Analog Source

CompactLogix Isolated Analog Input Module 19Publication 1769-IN074C-EN-P - March 2011Temperature, operating• IEC 60068-2-1 (Test Ad, Operating Col

Page 12

2 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011Important User InformationSolid-state equipment has operationa

Page 13 - Labeling the Terminals

20 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011Surge transient immunityIEC 61000-4-5±1 kV line-earth(CM) on

Page 14 - I/O Memory Mapping

CompactLogix Isolated Analog Input Module 21Publication 1769-IN074C-EN-P - March 2011Input SpecificationsAttribute 1769-IF4IAnalog normal operatin

Page 15 - Output Data File

22 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011Input Specifications (cont.)Attribute ValueAccuracy drift wit

Page 16 - Configuration Data Array

CompactLogix Isolated Analog Input Module 23Publication 1769-IN074C-EN-P - March 2011Additional ResourcesThese documents contain additional inform

Page 17 - 15 14131211109876543210

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Publication 1769-IN074C-EN-P - Mar

Page 18 - Specifications

CompactLogix Isolated Analog Input Module 3Publication 1769-IN074C-EN-P - March 2011North American Hazardous Location ApprovalThe following inform

Page 19 - Attribute 1769-IF4I

4 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011Environment and EnclosureATTENTION: This equipment is intended

Page 20

CompactLogix Isolated Analog Input Module 5Publication 1769-IN074C-EN-P - March 2011Module DescriptionItem Description Item Description1Bus lever

Page 21 - Input Specifications

6 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011Prevent Electrostatic DischargeRemove PowerSystem AssemblyThe

Page 22 - Input Specifications (cont.)

CompactLogix Isolated Analog Input Module 7Publication 1769-IN074C-EN-P - March 20111. Disconnect power.2. Check that the bus lever of the module

Page 23 - Certifications 1769-IF4I

8 CompactLogix Isolated Analog Input ModulePublication 1769-IN074C-EN-P - March 2011Grounding the ModuleMinimum SpacingMaintain spacing from enclo

Page 24 - Automation, Inc

CompactLogix Isolated Analog Input Module 9Publication 1769-IN074C-EN-P - March 20114. Drill and tap the mounting holes for the recommended M4 or

Commentaires sur ces manuels

Pas de commentaire