Publication 1747-UM003A-EN-P
4-32
Configuring The ControlNet Network with RSNetWorx™ for
ControlNet
Start RSNetWorx for ControlNet by double clicking on its icon. The following
screen appears:
At this point, you could configure your ControlNet network off-line and then
download it to the network. This example, instead, goes on-line and configure
the network. Therefore, click on the on-line icon or click on the Network
pull-down menu and select On-line.
A Browse for Network window appears, where you must select the
communication path previously configured in RSLinx for communicating
with your ControlNet network. In this example, a KTCX ControlNet PC card
was used. Click on the KTCX15 card to select it and then click OK.