Rockwell-automation 1734-IK Encoder/Counter Modules User Manual Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Rockwell-automation 1734-IK Encoder/Counter Modules User Manual. Rockwell Automation 1734-IK Encoder/Counter Modules User Manual User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 68
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Encoder/Counter
Modules
1734-IJ and 1734-IK
User Manual
Vue de la page 0
1 2 3 4 5 6 ... 67 68

Résumé du contenu

Page 1 - Encoder/Counter

Encoder/Counter Modules1734-IJ and 1734-IKUser Manual

Page 2 - Important User Information

Publication 1734-UM006B-EN-P - August 2005Preface 4Operational Mode Zero Frequency Detection Input MonitoredCounter No NoneEncoder No NonePerio

Page 3 - Summary of Changes

1 Publication 1734-UM006B-EN-P - August 2005Chapter 1About the ModulesWhat This Chapter ContainsRead this chapter to learn about types, features, and

Page 4 - Summary of Changes 2

Publication 1734-UM006B-EN-P - August 20051-2 About the ModulesOperating ModesThe encoder/counter modules operate in the modes shown in the tab

Page 5 - Table of Contents

Publication 1734-UM006B-EN-P - August 2005About the Modules 1-3Example of Counter ModeEncoder ModeThe encoder mode reads incoming pulses and re

Page 6

Publication 1734-UM006B-EN-P - August 20051-4 About the ModulesEXAMPLEExample of Multiplying Encoder Mode X1 X1 Multiplying Encoder ModeQuadrat

Page 7 - Who Should Use This

Publication 1734-UM006B-EN-P - August 2005About the Modules 1-5Period / Rate ModeThe Period/Rate Mode will return an incoming frequency and a t

Page 8 - Documentation

Publication 1734-UM006B-EN-P - August 20051-6 About the ModulesRelationship Between Sampled Pulses and Input FrequencyScaling the input frequen

Page 9 - Definitions

Publication 1734-UM006B-EN-P - August 2005About the Modules 1-7Rate Measurement ModeThe Rate Measurement mode determines the frequency and tota

Page 10

Publication 1734-UM006B-EN-P - August 20051-8 About the ModulesNew Data IndicatorA two-bit counter, C1 & C0, updates every time an "ev

Page 11 - About the Modules

Publication 1734-UM006B-EN-P - August 2005About the Modules 1-9Operating Mode FeaturesThe following table summarizes which features are active

Page 12 - Operating Modes

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Page 13 - Continuously

Publication 1734-UM006B-EN-P - August 20051-10 About the ModulesGate/Reset terminal is high. Counting resumes on the falling edge of the pulse

Page 14 - X4 Multiplying Encoder Mode

1 Publication 1734-UM006B-EN-P - August 2005Chapter 2Install the ModuleWhat This Chapter ContainsRead this chapter for information about how to instal

Page 15 - Example of Period/Rate Mode

Publication 1734-UM006B-EN-P - August 20052-2 Install the ModuleUse these Series C modules with the following:• ControlNet adapters with RSLogi

Page 16 - Operation of Scalar

Publication 1734-UM006B-EN-P - August 2005Install the Module 2-3Install the Mounting Base and Wiring Base AssemblyThe wiring base assembly (173

Page 17 - About the Modules 1-7

Publication 1734-UM006B-EN-P - August 20052-4 Install the Module3. Press firmly to seat the mounting base on the DIN rail. The mounting base sn

Page 18 - Default Configuration

Publication 1734-UM006B-EN-P - August 2005Install the Module 2-5Install the ModuleInstall the module before or after base installation. Make su

Page 19 - Operating Mode Features

Publication 1734-UM006B-EN-P - August 20052-6 Install the ModuleThe module locks into place.Install the Removable Terminal BlockA removable ter

Page 20 - Store-Reset/Start

Publication 1734-UM006B-EN-P - August 2005Install the Module 2-73. If an I/O module is installed, snap the RTB handle into place on the module.

Page 21 - Install the Module

Publication 1734-UM006B-EN-P - August 20052-8 Install the ModuleTermination Definition0A1Aret2B3Bret4Z5Zret6 Chassis ground7 Chassis ground4201

Page 22 - ATTENTION

Publication 1734-UM006B-EN-P - August 2005Install the Module 2-9Communicate with Your Module POINT I/O modules send (consume) and receive (prod

Page 23 - Install the Mounting Base

1 Publication 1734-UM006B-EN-P - August 2005Summary of ChangesThis publication contains new and revised information not in the last release.New and Re

Page 24 - 2-4 Install the Module

Publication 1734-UM006B-EN-P - August 20052-10 Install the ModuleModule ConfigurationParameter Set/Get Description Bytes1 Set/Get Counter Confi

Page 25

Publication 1734-UM006B-EN-P - August 2005Install the Module 2-11Assumes a 50% duty cycle signal.Filter Selection07 06 05 04 03 02 01 000ZFBFAF

Page 26 - Terminal Block

Publication 1734-UM006B-EN-P - August 20052-12 Install the ModuleAssembliesThe Encoder and Counter Module uses several words to communicate rea

Page 27 - Wire the Modules

1 Publication 1734-UM006B-EN-P - August 2005Chapter 3Input and Output DataThat This Chapter ContainsRead this chapter to learn about the input/output

Page 28

Publication 1734-UM006B-EN-P - August 20053-2 Input and Output DataDetailed Description of Data Table InformationPresent Channel Data (Input Wo

Page 29 - Communicate with Your

Publication 1734-UM006B-EN-P - August 2005Input and Output Data 3-3Bit definitions for the error code are:E10: ReservedE9: The decimal point po

Page 30 - Counter Configuration

Publication 1734-UM006B-EN-P - August 20053-4 Input and Output DataZero frequency Detected (ZD) - This bit is operational when frequency config

Page 31 - Scalar Selection

Publication 1734-UM006B-EN-P - August 2005Input and Output Data 3-5Counter Configuration (Configuration Word 1)Use this byte to select the type

Page 32 - Assemblies

Publication 1734-UM006B-EN-P - August 20053-6 Input and Output DataDecimal Position (Configuration Word 3)This byte changes the significant dig

Page 33 - Input and Output Data

Publication 1734-UM006B-EN-P - August 2005Input and Output Data 3-7Scalar (Configuration Word 7)This bytel scales the Z signal in the period/ra

Page 34 - Data Table Information

Publication 1734-UM006B-EN-P - August 2005Summary of Changes 2Notes:

Page 35

Publication 1734-UM006B-EN-P - August 20053-8 Input and Output DataSafe State Values (Configuration Word 10)When either the host transitions to

Page 36 - Configuration Data

1 Publication 1734-UM006B-EN-P - August 2005Chapter 4Configure Your ModuleWhat This Chapter ContainsThis chapter describes how to configure your Encod

Page 37

Publication 1734-UM006B-EN-P - August 20054-2 Configure Your Module2. Add the communication device as shown below. (In this case, the chosen de

Page 38 - Word 4 is reserved

Publication 1734-UM006B-EN-P - August 2005Configure Your Module 4-3The out-of-the-box node setting for 1734 modules is 63. You can change the s

Page 39 - Preset (Configuration Word 9)

Publication 1734-UM006B-EN-P - August 20054-4 Configure Your ModuleSet Counter ParametersAfter adding the module to the network, you must confi

Page 40 - Information

Publication 1734-UM006B-EN-P - August 2005Configure Your Module 4-5The module’s name appears here.Type a description here.The module’s address

Page 41 - Configure Your Module

Publication 1734-UM006B-EN-P - August 20054-6 Configure Your ModuleCheck I/O Status and View the EDS FileView the I/O defaults setup, and the E

Page 42 - IMPORTANT

Publication 1734-UM006B-EN-P - August 2005Configure Your Module 4-7Click on View File to view the actual EDS file.Click on the EDS File tab to

Page 43

Publication 1734-UM006B-EN-P - August 20054-8 Configure Your ModuleNotes:

Page 44 - Set Counter Parameters

1 Publication 1734-UM006B-EN-P - August 2005Chapter 5Access Instantiated InstancesWhat This Chapter ContainsIn this chapter, you learn how to access i

Page 45

v Publication 1734-UM006B-EN-P - August 2005Table of ContentsPrefacePrefacePurpose of This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 46 - Check I/O Status and View

Publication 1734-UM006B-EN-P - August 20055-2 Access Instantiated InstancesThe Class Instance Attribute editor dialog appears.For example:If yo

Page 47

Publication 1734-UM006B-EN-P - August 2005Access Instantiated Instances 5-3AssembliesAvailable assemblies are:• Assembly 101 is produced for a

Page 48

Publication 1734-UM006B-EN-P - August 20055-4 Access Instantiated Instances#106 (0x6a) Set/Get Counter Configuration 1Filter Selection 1Decimal

Page 49 - Access Instantiated Instances

1 Publication 1734-UM006B-EN-P - August 2005Chapter 6Troubleshoot the Module

Page 50 - For example:

Publication 1734-UM006B-EN-P - August 20056-2 Troubleshoot the ModuleIndication Probable CauseNetwork StatusOff Device is not online.- Device h

Page 51

1 Publication 1734-UM006B-EN-P - August 2005 Appendix AConfigure Modules in RSLogix 5000 SoftwareWhat This Appendix ContainsRead this appendix for in

Page 52

Publication 1734-UM006B-EN-P - August 2005A-2 Configure Modules in RSLogix 5000 SoftwareWhen you change Connection and Data Format, note the fo

Page 53 - Troubleshoot the Module

Publication 1734-UM006B-EN-P - August 2005Configure Modules in RSLogix 5000 Software A-3Configure Your ModuleTo configure your module in RSLogi

Page 54

Publication 1734-UM006B-EN-P - August 2005A-4 Configure Modules in RSLogix 5000 SoftwareWork with the Fault/Program Action DialogIn Hard Run m

Page 55

Publication 1734-UM006B-EN-P - August 2005Configure Modules in RSLogix 5000 Software A-5Work with the Counter Configuration DialogComplete entr

Page 56

vi Publication 1734-UM006B-EN-P - August 2005Chapter 3Input and Output DataWhat This Chapter Contains . . . . . . . . . . . . . . . . . . . . . . . 3

Page 57 - Use the Help Button

Publication 1734-UM006B-EN-P - August 2005A-6 Configure Modules in RSLogix 5000 Software3. Refer to the table to make selections for the follow

Page 58 - Fault/Program Action

Publication 1734-UM006B-EN-P - August 2005Configure Modules in RSLogix 5000 Software A-74. For Filter, select the Frequency from the following,

Page 59 - Configuration Dialog

Publication 1734-UM006B-EN-P - August 2005A-8 Configure Modules in RSLogix 5000 SoftwareWhen the value for Scalar is one of the following, freq

Page 60

Publication 1734-UM006A-EN-P - August 2000IndexAadding modules to the network 4-2adding the communication device 4-2assembly selection 3-8Bbase assemb

Page 61

Publication 1734-UM006A-EN-P - August 20002 IndexSsafe state configuration 3-8scalar 3-7scalar operation 1-6setting counter parameters 4-4setti

Page 62

Publication CIG-CO521C-EN-P- May 2003 PN957782-91How Are We Doing?Your comments on our technical publications will help us serve you better in the fu

Page 63

Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST

Page 65 - How Are We Doing?

Publication 1734-UM006B-EN-P - August 2005 6 PN 957974-39Supersedes Publication 1734-UM006A - August 2000 © 2005 Rockwell International Corporation.

Page 66 - BUSINESS REPLY MAIL

1 Publication 1734-UM006B-EN-P - August 2005PrefacePurpose of This ManualRead this manual for information about how to install, configure and troubles

Page 67

Publication 1734-UM006B-EN-P - August 2005Preface 2Related Products and DocumentationFor specification, safety approval, and other information

Page 68 - Back Cover

Publication 1734-UM006B-EN-P - August 2005Preface 3Definitions The following define the intended operation of the Encoder/Counter module.Term D

Commentaires sur ces manuels

Pas de commentaire