Rockwell-automation 1734-8CFGDLX POINT I/O Module with 8 Configurable Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Rockwell-automation 1734-8CFGDLX POINT I/O Module with 8 Configurable . Rockwell Automation 1734-8CFGDLX POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix IN User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation Instructions
POINT I/O Module with 8 Configurable
24V DC Points and DeviceLogix
Catalog Numbers 1734-8CFGDLX
Topic Page
Important User Information 2
Environment and Enclosure 3
Prevent Electrostatic Discharge 4
About the Module 4
Before You Begin 5
Install the Mounting Base 6
Install the Module 7
Install the Removable Terminal Block 9
Wire the Module 11
Wiring Diagram 12
Configure the Module 13
Interpret the Indicators 20
Specifications 23
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - 24V DC Points and DeviceLogix

Installation InstructionsPOINT I/O Module with 8 Configurable 24V DC Points and DeviceLogixCatalog Numbers 1734-8CFGDLX Topic PageImportant User Inf

Page 2 - Important User Information

10 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Install a 1734-TOPS Base1. Position

Page 3 - Environment and Enclosure

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 11Publication 1734-IN039A-EN-P - March 2009Wire the ModuleSee the figure and tab

Page 4 - About the Module

12 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Wiring DiagramChannel Terminal Numbe

Page 5 - Before You Begin

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 13Publication 1734-IN039A-EN-P - March 2009Configure the ModuleRead this section

Page 6 - Install the Mounting Base

14 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009You can select other produced assemb

Page 7 - Install the Module

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 15Publication 1734-IN039A-EN-P - March 2009Default Data Map - Consumed Assembly

Page 8 - 1734-TOP Base

16 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009You can select other consumed assemb

Page 9 - Remove a Mounting Base

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 17Publication 1734-IN039A-EN-P - March 2009Data [14] Masterless Produce PIT (ms)

Page 10 - Remove a 1734-TOPS Base

18 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Data [38] Peer 5 - EPR (ms)Data [39]

Page 11 - Wire the Module

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 19Publication 1734-IN039A-EN-P - March 2009Configuration of the 1734-8CFGDLX mod

Page 12 - Wiring Diagram

2 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Important User InformationSolid state

Page 13 - Configure the Module

20 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Interpret the IndicatorsSee the figu

Page 14

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 21Publication 1734-IN039A-EN-P - March 2009Network StatusStatus Description Reco

Page 15 - Publication

22 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009DeviceLogix StatusI/O StatusStatus D

Page 16

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 23Publication 1734-IN039A-EN-P - March 2009Specifications S

Page 17

24 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009General Specifications Attribute Val

Page 18

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 25Publication 1734-IN039A-EN-P - March 2009Environmental Specifications Attribut

Page 19 - RSNetWorx for DeviceNet

26 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009EFT/B immunity IEC 61000-4-4: ±3 kV

Page 20 - Interpret the Indicators

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 27Publication 1734-IN039A-EN-P - March 2009CertificationsCertification (when pro

Page 21 - Network Status

Publication 1734-IN039A-EN-P - March 2009 PN 41923Copyright © 2009 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Rockwell Automa

Page 22 - I/O Status

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 3Publication 1734-IN039A-EN-P - March 2009Environment and EnclosureATTENTIONThis

Page 23

4 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Prevent Electrostatic Discharge Ab

Page 24 - General Specifications

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 5Publication 1734-IN039A-EN-P - March 2009Before You BeginSee the figures to fam

Page 25 - Environmental Specifications

6 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Install the Mounting BaseFollow these

Page 26

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 7Publication 1734-IN039A-EN-P - March 2009Install the ModuleThe module can be in

Page 27 - Certifications

8 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 20091734-TOP BaseFollow these steps to in

Page 28 - Installation Assistance

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 9Publication 1734-IN039A-EN-P - March 2009Install the Removable Terminal BlockRe

Commentaires sur ces manuels

Pas de commentaire