44 PLC-5 Ethernet Interface Module
Publication 1785-IN019B-EN-P - January 2007
Monitor the series of blinks to determine the fault code. Count the first and last series of slow
blinks, and disregard the series of fast blinks between the slow series.
Module Error Codes
When the status LED blinks red, it signals that a hardware or software fault has been detected
and it reports the error via a code. This code is a two-digit fault code signaled by a flash
sequence. First, the LED begins the sequence with 10 rapid flashes. Then the LED signals the
first digit of the code by a number of slow flashes. Approximately two seconds after the LED
displays the first digit, the LED displays the second digit. This sequence repeats itself until the
module is either reset or replaced.
The following table lists controller fault codes relating to the interface module.
IMPORTANT
The interface module will flash the indicator lights as shown in the
Module Error Codes table. The controller may fault even though the
module does not.
Code Description Code Description
01 General 68000 test failure 36 PLC-5 dual-port initialization failure
02 Bus error 37 PLC-5 not compatible with 1785-ENET
03 Address error 38 Dual-port diagnostic failure
04 Illegal instruction 41 Could not read FLASH id
05 Divide by zero 42 Could not erase FLASH bank
06 Reserved 43 Could not program FLASH bank
07 Reserved 51 Software initialization failure
08 Privileged instruction 52 ENET firmware hardware fault
09 Trace trap 53 ENET software failure
10 Line 1010 instruction 54 Network system failure
11 Line 1111 instruction 55 Dual-port system failure
12 Hardware breakpoint 56 Dual-port internal inconsistency
13 Reserved 57 ISR system failure
14 Uninitialized interrupt 58 ISR internal inconsistency
15 Format error 61 Lump system call failed
16 Reserved 62 Lump internal inconsistency
24 Spurious interrupt 63 PCCC system call failed
25 TRAP in instruction 64 PCCC internal inconsistency
26 Unassigned user 65 Dual-port system call failed
27 Unassigned reserved 66 Dual-port internal inconsistency
31 OS area checksum not valid 71 AC power fail
32 Static RAM self-test failed 72 Reset asserted
33 Jump table wrong 73 Fault asserted
34 Ethernet chip test failed 74 Watchdog timeout
35 FLASH BOOT area checksum incorrect 75 Unknown NMI