H—1
A- - November 2000 –2000
H.
RSLinx is a windows based communication software package developed by Rockwell
Software to interface to all of the Rockwell and A-Bindustrial control and automation
hardware.RSLinxcomesinavarietyofdifferentflavorsincluding
RSLinx-Lite–PLCProgrammingsoftwarecommunicationinterface.
RSLinx-OEM–ProvidesDDEcapabilityforRockwellDDEcapablesoftware.
RSLinxProfessional–ProvidesDDEcapabilitytoandDDEcapablesoftware.
RSLinx-Gateway–Communicationnetworkbridgeing,routing,andOPCserver.
RSLinxSDK–SoftwareDevelopmentKitincludestheOEMversion.
Inactuality,alloftheRSLinxsoftwarepackagesarethesame.Whatdifferentiatesthe
softwarepackagesfromoneotheristhecopyprotectionsoftwarekeyforRSLinx.Ifyou
runRSLinxwithoutasoftwarekeythesoftwareoperatesintheLitemode.Ifyouhavea
keythesoftwareoperatesinthemodethatthesoftwarekeyauthorizesittorunin.
This appendix is going to explore the capabilities of RSLinx-Lite. However, the driver
configurationssectionsareapplicabletoallusesofRSLinx.
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - A- - November 2000  –2000

H—1A- - November 2000  –2000H.RSLinx is a windows based communication software package developed by RockwellSoftware to interface to a

Page 2

H—10A- - November 2000  –2000d- BrowsingIftheAutobrowse box is checkedand the AB_DF1-1 driverisselectedbyclickingonitwiththemouse8

Page 3

H—11A- - November 2000  –2000RSLinxcanalsoprovidediagnosticinformationoneachdeviceandonthedriverbyrightclickingonthedeviceandcho

Page 4 - H.2.2 RSLinx

H—12A- - November 2000  –2000. Half-DuplexmodeisoftenusediftheserialportisconnectedtoanOperatorInterface.

Page 5

H—13A- - November 2000  –2000H.3The A-B KT driver is generally usedwhen communicating overa DH+ (DataHighwayPlus)network.However,the

Page 6

H—14A- - November 2000  –2000H.3.2OnceaphysicalDH+connectionisinplacebetweenourprogrammingPCandthePLCthenextstepissettingupRSLin

Page 7 - DeviceListed RealDevice

H—15A- - November 2000  –2000TheConfigureDriverswindowiswhereallnewcommunicationinterfacesareadded,andwhereexistingdriversareconfigu

Page 8

H—16A- - November 2000  –2000TheKT/DH+driveristhe1784-KT/KTX(D)/PKTX(D)choiceinthelistbox.Selectthe1784-KT/KTX(D)/PKTX(D)choicebyclic

Page 9

H—17A- - November 2000  –2000To change the Device Type click the drop down arrow in the Value box. The followingchoices will appear

Page 10

H—18A- - November 2000  –2000TheStationNumberisthenextentry.TheStationNumberistheDH+addressofthisprogrammingcomputerontheDH+net

Page 11

H—19A- - November 2000  –2000TheBoardAddressisthenextentry.TheBoardAddressisactuallysetbydipswitchesontheKTcarditself.Tosetthe

Page 12

H—2A- - November 2000  –2000H.1RSLinx is the intermediary between the communication hardware and the softwarepackagethatneedsdatafrom

Page 13

H—20A- - November 2000  –2000Thenext entryistheInterrupt.AsageneralruletheInterruptvalueshouldbeleftatNone,.Thelastparameterto

Page 14

H—21A- - November 2000  –2000Iftheconfigurationeverneedstobechanged,suchasstationnumber,comebacktothisscreenselecttheKTdriverby

Page 15

H—22A- - November 2000  –2000d- BrowsingIftheAutobrowseboxischeckedandtheAB_KT-1driverisselectedbyclickingonitwiththe mouse8  the

Page 16

H—23A- - November 2000  –2000e-IftheKTdriverdoesnotappearasrunningorshowsanERRORindicationintheconfiguredriversdialogwindow,then

Page 17

H—24A- - November 2000  –2000H.4

Page 18

H—25A- - November 2000  –2000H.5

Page 19

H—3A- - November 2000  –2000H.2TheA-BserialdriveruseswhatiscalledtheDF1protocoltoprovidePCtoPLC,pointtopoint,communications.Thek

Page 20

H—4A- - November 2000  –2000H.2.2 RSLinxOnceaphysicalserialconnectionisinplacebetweenourprogrammingPCandthePLCthenextstepissetting

Page 21

H—5A- - November 2000  –2000TheConfigureDriverswindowiswhereallnewcommunicationinterfacesareadded,andwhereexistingdriversareconfigur

Page 22

H—6A- - November 2000  –2000TheserialdriveristheRS-232DF1Deviceschoiceinthelistbox.SelecttheRS-232DF1Deviceschoicebyclickingoni

Page 23

H—7A- - November 2000  –2000TheConfigureDF1CommunicationsDevicewindowiswhereallofthecriticalcommunicationconfigurationinformationisen

Page 24

H—8A- - November 2000  –2000ThankfullytheRSLinxsoftwarecaninterrogatetheserialportsettingsonthePLCandchangetheRSLinxsoftwaresetting

Page 25

H—9A- - November 2000  –2000Inthiscaseauto-configurationwassuccessfulandtheBaudRatewasfoundtobe2400.Ifauto-configurationissuccessfu