Triguard
SC300E
MBB
Bus Extender Module
(
MBB)
Issue
4 October
2006
INTRODUCTION
AND
TEC
HNICAL
DATA
PURPOSE
An
MBB
Bus
Extender
Module
is
located
in
each
of
the
three
right
-
hand
slots
of
any
local
extension
chassis
that
is
not
connected
to
a remote
extension
chassis.
The
thre
e MBBs
(A,
B
and
C)
provide
an
opto
-
isolated
interface
between
the
I/O
modules
in
the
extension
chassis
and
the
processor
modules
(MPPs)
in
the
main
chassis.
Figure
2
-
1 shows
how
the
MPPs
and
MBBs
are
all
linked
by
ribbon
cables
running
between
expansion
bus
connectors
‘A’,
‘B’
and
‘C’
on
the
chassis
backplanes.
Up
to
14
extension
chassis
can
be
linked
to
a single
main
chassis
in
this
way.
This
document
is
intended
to
provide
a general
understanding
of
the
function
of
the
bus
extender
module
sufficient
to
enable
basic
maintenance
operations
to
be
effected
in
the
field
ASSOCIATED DOCUMENTATION
Reference
No
Title
008
-
5097
Chassis
User
Manual
008
-
5100
MPP
Processor
Module
User
Manual
008
-
5115
TBA
Bus
Expansion
Adaptor
User
Manual
008
-
5217
TBT
Bus
Terminator
User
Manual
008-5105
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Bus Extender Module

Triguard SC300E MBB Bus Extender Module (MBB) Issue 4 October 2006 INTRODUCTION AND TECHNICAL DATA PURPOSE An MBB Bus Extender Module is located in ea

Page 2

10MBBOctober2005–Issue 4Triguard SC300E Figure 2-5 Chassis address link coding

Page 3 - MBB October 2005

MBB October 2005–Issue 411Triguard SC300E MBB Bus Extender Module SERVICING SCOPE The MBB is not field repairable. Field servicing operations are conf

Page 4

12MBBOctober2005–Issue 4Triguard SC300E SERVICE SUPPORT SPARE PARTS Spare parts and technical advice may be obtained from your local area office.

Page 5

2MBBOctober2005–Issue 4Triguard SC300E Figure 1-1 MBB General view and front panel detail SW1 (not used) IC1 (FPGA) Connector J1 Connector J2

Page 6

MBB October 2005–Issue 43Triguard SC300E MBB Bus Extender Module SPECIFICATION Model MBB Indicators Health Module power consumption 2.2W Overall size

Page 7 - Triguard

4MBBOctober2005–Issue 4Triguard SC300E TECHNICAL DESCRIPTIONPHYSICAL The MBB is a 9U high PCB with integral front panel. A general view is shown in Fi

Page 8

MBB October 2005–Issue 45Triguard SC300E MBB Bus Extender Module Figure 2-1 Local chassis interconnections Table 2-1. Connector location and type Conn

Page 9

6MBBOctober2005–Issue 4Triguard SC300E EXTENSION CHASSIS ADDRESSING The chassis address is set up on links on the chassis backplane. The physical loca

Page 10

MBB October 2005–Issue 47Triguard SC300E MBB Bus Extender Module Figure 2-2 Backplane bus interconnections

Page 11 - SERVICING

8MBBOctober2005–Issue 4Triguard SC300E 0123UNIT ID 0123UNIT ID 0123UNIT ID Figure 2-3 MBB Related backplane connectors

Page 12 - SPARE PARTS

MBB October 2005–Issue 49Triguard SC300E MBB Bus Extender Module Figure 2-4MBB -Block diagram