204 Motion Blocks
Note that if the master axis is not moving, you can achieve this same
effect using another position-lock cam block with a new master reference
position. The phase shift move, however, allows this adjustment to be
made at a controlled rate while the master is moving and the position-lock
cam is executing.
You can use phase shift moves to provide slip compensation for the
master axis when you use a position-lock cam. In such a case, the amount
of slip can be determined using the standard registration capability. A
phase shift Move Axis block can smoothly adjust the position-lock cam
profile by the slip distance.
Rotary Shortest Path Moves
Rotary Shortest Path moves a rotary Axis to the desired absolute position
via the shortest path. It is a special type of absolute move available only
for rotary axes.
!
ATTENTION:
Use Rotary Shortest Path moves only
with rotary axes, and never with linear axes.
.
Master Axis Position
Slave Axis Position
Profile Stored
in Cam Tables
Profile After Phase Shift
Move of Slave Axis
Profile After Incremental
Move of Slave Axis
Vue de la page 240