5 DATABASE MAINTENANCE
37
• • • • •
4. Rename the entek.dbs file to the name of the directory. In this picture, the new
database and directory are named Newtest.
5. Start the SQLConsole if it is not running (select Start > Programs > Gupta >
SQLBase 9.0.1 > SQLConsole DBA Utility).
6. Right-click the server name in the SQLConsole display, and then select Manage
Database > Install.
7. Enter the name of the new database that you created steps 1-4, and then click Install.
The new database appears in the tree under the database server name.