Rockwell-automation 6181F_P Series E Integrated Display Computers Inst Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
Industrial Integrated Display Computers 13
Rockwell Automation Publication 6181P-IN010F-EN-P - July 2013
Install the Computer
The computers support the following mounting options:
Panel mount
Wall mount (for non-display computers)
Panel Mounting Guidelines
Observe these guidelines when installing the computer in a panel:
Remove all electrical power from the panel before making the cutout.
Confirm that there is adequate space behind the panel. For specific information, refer to
Mounting Clearances
on page 8.
Cut supporting panels to specifications before installation. Take precautions so metal
cuttings do not enter components already installed in panel.
Supporting panels must be at least 14 gauge for proper sealing against water and dust,
and to provide proper support. The mounting hardware supplied accommodates panel
thickness 1.5…5.5 mm (0.06…0.25 in.).
Make sure the area around the panel cutout is clear.
Panel Cutout Dimensions
The computers must be mounted to meet the panel cutout dimensions specified below.
Included with the computer is 6181P and 6181X Industrial Computers Cutout Template,
publication 6181P-DS002
, with a cutout template for each display computer model.
ATTENTION: Failure to follow these guidelines can result in personal injury or damage to the panel
components.
Computer Model Cutout Dimensions (H x W), approx
1200P 254.0 x 324.0 mm (10.0 x 12.76 in.)
1500P 285.0 x 386.6 mm (11.24 x 15.22 in.)
1700P 329.5 x 424.0 mm (12.97 x 16.69 in.)
Vue de la page 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 23 24

Commentaires sur ces manuels

Pas de commentaire