Vue de la page 124
Application Examples E–9
Publication 2755-6.9
Configuration Codes for the SLC 5/03 and SLC 5/04 Controllers
After making the necessary connections, set the reader to the settings
in the table below to allow the reader to communicate with the SLC
5/03 or SLC 5/04 controllers.
Description Menu Setting Serial Command Setting
Preamble Disable <Kd0>
Postamble Enable Control J <Kel,^M,^J>
Baud Rate 9600
Parity None
Stop Bits One
<Ka4,0,0,1>
Data Bits 8
SLC 5/03 and SLC 5/04 Controllers Setup
You need to configure the SLC 5/03 and SLC 5/04 controllers.
Follow the steps starting below or refer to the following publications:
SLC 500 Modular Hardware Style Installation and Operation
Manual (Publication No. 1747-6.2)
SLC 500 and MicroLogixt 1000 Instruction Set Reference
Manual (Publication No. 1747-6.15)
Advanced Programming Software User Manual
(Publication No. 9399-APSUM-11.15.95)
1. Set the SLC Channel 0 to User in the Channel 0 Configuration
screen