Vue de la page 82
4–41Creating Message Files
Publication 2706-6.2
Communications via RS–485
Test Message Selections (for RS-485 communications)
If communicating via RS-485, the Address Selections window
opens. Select the DL40 address; then press [ ]. If you need to
change your computers communications port parameters, highlight
Configure Port, and press [ ]. Select COM1 or COM2; press [ ].
The   window opens. Set Computer Address and
Baud Rate. Note: To change Parity or Data Bits, return to Ports
menu.
Highlight Download (filename) and press [ ]. After file is
downloaded, you will return to the Verify window. Highlight Test
Message(s) on DL40; press [ ].
The Message Selections window opens. Highlight number of the
message you want to display and press [ ]. Answer Yes to Start
Testing Messages Now? Message is displayed on DL40. Press
[ESC] to end an Autorepeat message.