74 Rockwell Automation Publication 750COM-UM001E-EN-P - October 2013
Chapter 4 Configuring the I/O
2. Expand the Communications group to display all of the available
communication modules.
3. Select ‘ETHERNET-MODULE’ from the list to configure the drive and
its embedded EtherNet/IP adapter.
4. Click OK.
The drive’s New Module dialog box appears.
5. Edit the following information about the drive and adapter.
Box Setting
Name A name to identify the drive and adapter.
Description Optional – description of the drive/adapter.
Comm Format Data - DINT (This setting formats the data in 32-bit words.)
IP Address The IP address of the adapter.
Open Module
Properties
When this box is checked, clicking OK opens additional module properties dialog
boxes to further configure the drive/adapter. When unchecked, clicking OK closes the
drive’s New Module dialog box. For this example, check this box.