Publication 2098-PM001E-EN-P — July 2002
2-30 Referencing the Motion Library
long CamModifiedSinusoidal(long master_position,long
follower_position);
Adds a modified sinusoidal curve to the table. The profile of a
normalized modified sinusoidal curve is shown in Figure 2.5.
The master_position argument defines the master position at the
end of the curve.
The follower_position argument defines the follower position at the
end of the curve.
Returns 0 if successful, or -1 if there was an error.
This function requires three free segments.
Figure 2.5
Modified Sinusoidal Curve
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.000 0.125 0.250 0.375 0.500 0.625 0.750 0.875 1.000
Master Position (dx)
Follower Position (dy)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0.000 0.125 0.250 0.375 0.500 0.625 0.750 0.875 1.000
Master Position (dx)
Follower Velocity (dy/dx)
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
0.000 0.125 0.250 0.375 0.500 0.625 0.750 0.875 1.000
Master Position (dx)
Follower Acceleration (dy/dx