Rockwell-automation 193-DNCT DeviceNet Configuration Terminal User Man Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Rockwell-automation 193-DNCT DeviceNet Configuration Terminal User Man. Rockwell Automation 193-DNCT DeviceNet Configuration Terminal User Manual User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 92
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
DeviceNet™ Configuration Terminal
Catalog Numbers 193-DNCT
User Manual
Vue de la page 0
1 2 3 4 5 6 ... 91 92

Résumé du contenu

Page 1 - User Manual

DeviceNet™ Configuration TerminalCatalog Numbers 193-DNCTUser Manual

Page 2 - ™ Configuration Terminal

6 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 1 Product OverviewNotes:

Page 3 - Important User Information

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 7Chapter 2Installation and WiringInstallation and WiringThe DNCT ships complete with a

Page 4 - Reference Manuals

8 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 2 Installation and Wiring193-DNCT-BZ1 Physical ConnectionsThe optional Cat.

Page 5

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 9Chapter 3Physical FeaturesPhysical Features Figure 1 - Cat. No. 193-DNCT Physical Fea

Page 6 - Table of Contents

10 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 3 Physical FeaturesKey DescriptionsShifted Key DescriptionsThe following t

Page 7

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 11Chapter 4Quick StartPowerupThe DeviceNet™ Configuration Terminal is shipped so that

Page 8

12 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 4 Quick StartTerminal SetupTo scroll through the items on the screen, pres

Page 9 - Product Overview

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 13Quick Start Chapter 4Ver s i on : Displays Version information for the selected d

Page 10 - Chapter 1 Product Overview

14 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 4 Quick StartChange a parameter value by first pressing the SEL key and th

Page 11 - Installation and Wiring

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 15Quick Start Chapter 4DeviceNet™ Configuration Terminal Setup MenusThe 193 DeviceNe

Page 12 - Powering the 193-DNCT

™ Configuration Terminal

Page 13 - Physical Features

16 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 4 Quick StartWho Menu DisplayThe Who Menu displays the device information

Page 14 - Shifted Key Descriptions

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 17Chapter 5Device Choices MenuDevice Choices MenuThe Device Choices menu is entered fr

Page 15 - Quick Start

18 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 5 Device Choices MenuStandard Device Status MenuThe 193-DNCT displays the

Page 16 - Terminal Setup

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 19Device Choices Menu Chapter 5Figure 1 - Fault Buffer with all optional attributes

Page 17 - Parameter Monitoring and

20 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 5 Device Choices Menukeypad can be used to attempt to clear the current wa

Page 18

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 21Chapter 6Parameter Choices MenuParameter Choices MenuThe Parameter Choices Menu is o

Page 19 - Port Object And Routing Sub

22 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 6 Parameter Choices MenuParameter Edit ScreensThe Parameter Edit Screens a

Page 20 - Who Menu Display

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 23Parameter Choices Menu Chapter 6parameters. Entering a new parameter number direct

Page 21

24 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 6 Parameter Choices Menuparameter value is selected, pressing the Esc key

Page 22 - Fault Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 25Parameter Choices Menu Chapter 6Enumerated ParametersParameters that display Value

Page 23 - Warning Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 iiiImportant User InformationBecause of the variety of uses for the products described

Page 24

26 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 6 Parameter Choices MenuParameters with Bit Enumerated data values are dis

Page 25 - Parameter Choices Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 27Parameter Choices Menu Chapter 6Entering floating point numbers is performed much

Page 26 - Parameter

28 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 6 Parameter Choices MenuParameter Display-Value Enumerated Certain paramet

Page 27 - Changing a Parameter Value

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 29Chapter 7Copy Cat MenuCopy CatThe copy cat menu allows the operator to upload and do

Page 28

30 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 7 Copy Cat Menufirst screen will allow the operator to select where the da

Page 29 - Enumerated Parameters

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 31Copy Cat Menu Chapter 7Once the parameters are uploaded, the DeviceLogix™ program

Page 30 - Floating Point Parameters

32 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 7 Copy Cat MenuAfter selecting the file to download, press the Enter key t

Page 31 - Parameters

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 33Copy Cat Menu Chapter 7If there are errors during the download process, the screen

Page 32 - Enumerated

34 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 7 Copy Cat MenuWhen a Copy Cat data file is downloaded to a different firm

Page 33 - Copy Cat Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 35Copy Cat Menu Chapter 7current range is different from that of the product that th

Page 34

iv Rockwell Automation Publication 193-UM009B-EN-P - February 2013Manual ObjectivesThe purpose of this manual is to provide you with the information n

Page 35 - Copy Cat Downloading

36 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 7 Copy Cat MenuDeleting Copy Cat FilesDeleting a Copy Cat file from the me

Page 36

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 37Chapter 8Tools MenuTools MenuThe Tools Menu gives the user access to the Node Commis

Page 37 - Product Revisions

38 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 8 Tools MenuThe Get service is outlined in the following screen descriptio

Page 38 - Product Current Ratings

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 39Tools Menu Chapter 8to an oscilloscope or chart recorder). The first screen allows

Page 39

40 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 8 Tools MenuGraph View ScreenThis menu displays the CIA data in graphical

Page 40 - DeviceLogix™ Library 5

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 41Tools Menu Chapter 8Pressing the Enter Key at the “Assembly Consumed / Produced” m

Page 41 - Tools Menu

42 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 8 Tools MenuNotes:

Page 42 - Graph Setup Screens

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 43Chapter 9Advanced Functions MenuAdvanced Functions MenuThe Advanced Functions Menu p

Page 43

44 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 9 Advanced Functions MenuNotes:

Page 44 - Produced Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 45Chapter 10HeartBeat MenusThe HeartBeat feature can be found in the Tools MenuThe use

Page 45 - Tools Menu Chapter 8

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 1Important User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 46 - Chapter 8 Tools Menu

46 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 10 Notes:

Page 47 - Advanced Functions Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 47Chapter 11I/O Message MonitoringI/O Message MonitoringThis screen displays I/O messa

Page 48

48 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 11 I/O Message MonitoringNotes:

Page 49 - HeartBeat Menus

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 49Chapter 12DeviceLogix™ FunctionalityDeviceLogix™ FunctionalityThe Configuration Term

Page 50 - Chapter 10

50 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 12 DeviceLogix™ FunctionalityBoolean Gates: AND, OR, XOR, NAND, NOR, NXOR

Page 51 - I/O Message Monitoring

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 51DeviceLogix™ Functionality Chapter 12Timers: On Delay, Off Delay and Pulse TimerDi

Page 52

52 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 12 DeviceLogix™ FunctionalityDeviceLogix™ Monitor. To create, edit or dele

Page 53 - DeviceLogix™ Functionality

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 53DeviceLogix™ Functionality Chapter 12Function BlocksThe 193-DNCT has function bloc

Page 54

54 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 12 DeviceLogix™ FunctionalityNotice that the current source bit assignment

Page 55 - DeviceLogix™ Editor

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 55Chapter 13Discrete I/O StatusDiscrete I/O StatusThe Discrete I/O Status screen is di

Page 56 - Creating a New Function

2 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Table of ContentsChapter 6Parameter Choices MenuParameter Choices Menu . . . . . . .

Page 57 - Function Block Inputs

56 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 13 Discrete I/O StatusNotes:

Page 58

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 57Chapter 14Zone Interlock Protocol (ZIP)Zone Interlock Protocol (ZIP) The Zone Interl

Page 59 - Discrete I/O Status

58 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 14 Zone Interlock Protocol (ZIP)Mapping Consumed ZIP DataThis section expl

Page 60

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 59Zone Interlock Protocol (ZIP) Chapter 14The following screen shows the EPR (Expect

Page 61 - Zone Interlock Protocol (ZIP)

60 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 14 Zone Interlock Protocol (ZIP)Use the Sel key to select the ZIP data tab

Page 62 - Mapping Consumed ZIP Data

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 61Zone Interlock Protocol (ZIP) Chapter 14When all edits are complete, the ZIP confi

Page 63

62 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 14 Zone Interlock Protocol (ZIP)Press the Right/ Left arrow keys to select

Page 64

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 63Chapter 15DeviceNet™ Scanner MenuDeviceNet™ Scanner MenuThe DeviceNet™ Scanner Menu

Page 65 - ZIP Data Table Monitor

64 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 15 DeviceNet™ Scanner MenuAutoScan FunctionThe Auto Scan screen allows the

Page 66

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 65Chapter 16Terminal Choices MenuTerminal Choices MenuThe Terminal Choices Menu is onl

Page 67 - DeviceNet™ Scanner Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 3Table of ContentsChapter 12DeviceLogix™ FunctionalityDeviceLogix™ Functionality . . .

Page 68 - Node Activation Screen

66 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 16 Terminal Choices MenuNote: It may take up to 10 seconds for the Faulted

Page 69 - Terminal Choices Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 67Terminal Choices Menu Chapter 16DeviceNet™ Error LogThe DeviceNet™ Error Log store

Page 70 - Offline Change Address

68 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 16 Terminal Choices MenuNotes:

Page 71 - Network Statistics Screen

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 69Chapter 17Terminal Setup MenuTerminal Setup MenuThis menu is used to configure featu

Page 72

70 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 17 Terminal Setup Menuand start proxying. It also allows all devices to co

Page 73 - Terminal Setup Menu

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 71Terminal Setup Menu Chapter 17Password Setup (Primary)To activate the primary pass

Page 74 - Password Menu

72 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 17 Terminal Setup MenuNote: Once the primary password is set, it must be l

Page 75 - Password Setup (Secondary)

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 73Terminal Setup Menu Chapter 17intervention at power-up. The following choices appe

Page 76 - Auto Display

74 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 17 Terminal Setup MenuProgrammable User Function Key SetupThe 5 user progr

Page 77 - AutoDisplay Test

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 75Terminal Setup Menu Chapter 17Function Key Setup Screen LCD ContrastThis screen is

Page 78 - Key Setup

4 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Table of ContentsChapter 17Terminal Setup MenuTerminal Setup Menu . . . . . . . . . .

Page 79 - LCD Contrast

76 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 17 Terminal Setup MenuNotes:

Page 80

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 77Chapter 18Copy and Paste FeatureCopy and Paste FeatureThe 193-DNCT has a Copy and Pa

Page 81 - Copy and Paste Feature

78 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 18 Copy and Paste FeatureScreen and select the parameter to copy. Press th

Page 82

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 79Chapter 19Menu Help FeatureMenu Help FeatureAll of the screens in the DeviceNet™ Con

Page 83 - Menu Help Feature

80 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 19 Menu Help FeatureNotes:

Page 84

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 81Chapter 20SpecificationsDisplayDisplay Type 128 x 64 LCD with yellow-green backlight

Page 85 - Specifications

82 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Chapter 20 SpecificationsDimensionsHeight 116 mm (4.57 in)Width 70 mm (2.76 in)Dep

Page 86

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 83Appendix ADeviceNet™ ObjectsThe following object classes are supported: Identity Obj

Page 87 - DeviceNet™ Objects

84 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Appendix A DeviceNet™ ObjectsThe following common services are implemented for the

Page 88 - DeviceNet™ Object

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 85DeviceNet™ Objects Appendix A Connection ObjectCLASS CODE 0x0005No class attribute

Page 89 - Connection Object

Rockwell Automation Publication 193-UM009B-EN-P - February 2013 5Chapter 1Product OverviewProduct Overview The 193-DNCT product is a handheld device t

Page 90

86 Rockwell Automation Publication 193-UM009B-EN-P - February 2013Appendix A DeviceNet™ ObjectsNotes:

Page 92 - Documentation Feedback

Publication 193-UM009B-EN-P - February 2013 PN-40754-656-02Supersedes Publication 193-UM009A-EN-P - December 2006 Copyright © 2013 Rockwell Automation

Commentaires sur ces manuels

Pas de commentaire