ArmorBlock is a trademark of Allen-Bradley Co. Inc.
Publication 1792-5.5 – October 1996
 

Cat. No. 1792-IB2XOB2E Series B
To: See page:
Install
the ArmorBlock
Module
3
Connect the Wiring to the ArmorBlock Module
8
Communicate with Y
our ArmorBlock Module
10
Configure Y
our ArmorBlock Module Of
fline Using the DeviceNet
Manager Configuration T
ool
11
Configure Y
our ArmorBlock Module Online Using the DeviceNet
Manager Configuration T
ool
17
Reset Faults 25
Configure Y
our ArmorBlock Module with EDS Files
27
For this reference information
See page:
Default Configuration
14
Status indicators
32
Troubleshooting 32
Specifications 34
This 1792 ArmorBlock I/O block module (Cat. No. 1792-IB2XOB2E)
contains I/O circuits, a built-in power supply, and a built-in DeviceNet
I/O adapter. Because of its sealed housing, this 1792 I/O block requires
no enclosure. It is compatible with PLC or SLC programmable
controllers using DeviceNet scanners. The I/O values are accessible
from the PLC or SLC programmable controller data table.
This ArmorBlock module has no switches to set. You set module
parameters using the DeviceNet Manager Software (cat. no.
1787-MGR) or similar configuration tool.
Installation Instructions
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - 

ArmorBlock is a trademark of Allen-Bradley Co. Inc.Publication 1792-5.5 – October 1996 Cat. No. 1792-IB2XOB2E Series

Page 2

ArmorBlock 2 Input/2 Output Module10Publication 1792-5.5 – October 1996Connecting the DeviceNet WiringConnect DeviceNet wiring to the 5-pin mini conn

Page 3 - 1770-KFD

11 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Bit07 06 05 04 03 02 01 00Produces IS Reserved OF1 OF0 I1 I0Consumes Reserved

Page 4

ArmorBlock 2 Input/2 Output Module12Publication 1792-5.5 – October 1996Adding a Device to the NetworkAction ResponseAt the network screen, click on t

Page 5 - Set new node

13 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Configure your Device ParametersAfter adding the devices to the network, you m

Page 6 - Mount the ArmorBlock Module

ArmorBlock 2 Input/2 Output Module14Publication 1792-5.5 – October 1996Configuring the ParametersDefault settings for the 2 in/2 out module are:autob

Page 7 - Mounting Dimensions

15 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 19962. Click on the radio button to select a different setting. To save thesetti

Page 8 - • the DeviceNet connector

ArmorBlock 2 Input/2 Output Module16Publication 1792-5.5 – October 1996Saving to a File1. To save those parameters to a file, click on the button.Yo

Page 9 - Connecting the Output Wiring

17 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 19962. Choose the file name, file type (.TXT), directory and drive to whichyou wan

Page 10

ArmorBlock 2 Input/2 Output Module18Publication 1792-5.5 – October 19962. The configuration screen for your selected driver appears. You can:• set th

Page 11 - Configure

19 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Add the Device to the NetworkAction ResponseAt the network screen, click on th

Page 12

ArmorBlock 2 Input/2 Output Module2Publication 1792-5.5 – October 1996European Union Directive ComplianceIf this product is installed within the Euro

Page 13

ArmorBlock 2 Input/2 Output Module20Publication 1792-5.5 – October 19964. Click once on the device you wish to configure on the project screenand cho

Page 14 - The parameter screen appears

21 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 19965. Load parameters.If you want to load parameters ChooseFrom a fileYou see thi

Page 15

ArmorBlock 2 Input/2 Output Module22Publication 1792-5.5 – October 19966. Modify the parameter.If you want to ChooseModify a parameterYou see a scree

Page 16

23 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 19967. Save parameters to a file, to the device, or print to a file.If you want to

Page 17

ArmorBlock 2 Input/2 Output Module24Publication 1792-5.5 – October 1996Monitoring Parameters OnlineYou can monitor parameters at the Device Configura

Page 18 - • set the data rate

25 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Reset FaultsThere are various ways to reset faults on an ArmorBlock module.• c

Page 19 - Add the Device to the Network

ArmorBlock 2 Input/2 Output Module26Publication 1792-5.5 – October 1996The device configuration screen appears. Select the Reset Faulted I/Oparameter

Page 20

27 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Reset Faults using Explicit Message Program ControlYou can also reset inputs a

Page 21 - 5. Load parameters

ArmorBlock 2 Input/2 Output Module28Publication 1792-5.5 – October 1996VendName = ”Allen–Bradley Company, Inc.”;ProdType = 7;ProdTypeStr = ”General P

Page 22 - 6. Modify the parameter

29 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996”Enable takes effect after next powerup. Disable is required to set fixed bau

Page 23

3 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Install Your ArmorBlock ModuleInstallation of the ArmorBlock module consists of

Page 24 - Parameters Online

ArmorBlock 2 Input/2 Output Module30Publication 1792-5.5 – October 1996”Defines output behavior in the event of a communication fault.”,0,1,0, $ Min,

Page 25 - Reset Faults

31 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$

Page 26

ArmorBlock 2 Input/2 Output Module32Publication 1792-5.5 – October 19960, $ reserved6, $ Link Path Size”20 09 24 02 30 04”, $ Link Path to Output 2 s

Page 27

33 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Note: This module contains a circuit to protect the DeviceNet power supply fro

Page 28

ArmorBlock 2 Input/2 Output Module34Publication 1792-5.5 – October 1996Specifications2 Input/2 Output Module – 1792-IB2XOB2E/BInput SpecificationsInp

Page 29

35 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 19962 Input/2 Output Module – 1792-IB2XOB2E/BGeneral SpecificationsIndicators Mod/

Page 30

ArmorBlock 2 Input/2 Output Module36Publication 1792-5.5 – October 19962 Input/2 Output Module – 1792-IB2XOB2E/BEnvironmental ConditionsOperational T

Page 31

ArmorBlock 2 Input/2 Output Module4Publication 1792-5.5 – October 19962. Using DeviceNet Manager Software, go online using the “SetupOnline Connectio

Page 32 - • Input fault indicator

5 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 19965. The bar at the bottom of the screen will tell you when you go online.6. At t

Page 33

ArmorBlock 2 Input/2 Output Module6Publication 1792-5.5 – October 1996Mount the ArmorBlock ModuleMount the block module directly to the machine or de

Page 34 - Specifications

7 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Mounting Dimensions6.242.632.57.741.903.0554 mounting holesfor #10 screws(77.6)

Page 35

ArmorBlock 2 Input/2 Output Module8Publication 1792-5.5 – October 1996Connect the Wiring to the ArmorBlock ModuleThe block module uses quick disconne

Page 36 - Worldwide representation

9 ArmorBlock 2 Input/2 Output ModulePublication 1792-5.5 – October 1996Connecting the Input WiringConnect input wiring to the micro connectors which s

Commentaires sur ces manuels

Pas de commentaire