Publication 1771ĆIN034B-EN-P - August 2002
DC (10Ć30V) Output Module
(Cat. No. 1771-OBN Series B)
Use this document as a guide when installing the catalog number
1771-OBN series B output module.
To See page
Important User Information 1
Preinstallation Considerations 4
Calculate Power Requirements 5
Key the Backplane Connector 5
Install the Module and Field Wiring Arm 6
Connect Wiring to the Field Wiring Arm 7
For this reference information See page
Interpreting the Status Indicators 10
Replacing the Fuses 10
Hazardous Location Approval 11
Specifications 12
Because of the variety of uses for the products described in this
publication, those responsible for the application and use of these
products must satisfy themselves that all necessary steps have been
taken to assure that each application and use meets all performance
and safety requirements, including any applicable laws, regulations,
codes and standards. In no event will Rockwell Automation be
responsible or liable for indirect or consequential damage resulting
from the use or application of these products.
Any illustrations, charts, sample programs, and layout examples
shown in this publication are intended solely for purposes of
example. Since there are many variables and requirements associated
with any particular installation, Rockwell Automation does not
assume responsibility or liability (to include intellectual property
liability) for actual use based upon the examples shown in this
publication.
Allen–Bradley publication SGI–1.1, Safety Guidelines for
Application, Installation, and Maintenance of Solid–State Control
(available from your local Rockwell Automation office), describes
some important differences between solid–state equipment and
electromechanical devices that should be taken into consideration
when applying products such as those described in this publication.
Installation Instructions
Contents
Important User
Information
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - DC (10Ć30V) Output Module

Publication 1771ĆIN034B-EN-P - August 2002DC (10Ć30V) Output Module(Cat. No. 1771-OBN Series B)Use this document as a guide when installing the catalo

Page 2 - DC (10-30V) Output Module2

DC (10-30V) Output Module10Publication 1771ĆIN034B-EN-P - August 2002The module has 32 status indicators on the module front plate. Theserepresent th

Page 3 - DC (10-30V) Output Module 3

DC (10-30V) Output Module 11Publication 1771ĆIN034B-EN-P - August 2002The following information applies when operating this equipment in hazardous lo

Page 4 - Considerations

DC (10-30V) Output Module12Publication 1771ĆIN034B-EN-P - August 2002Outputs per module 32 (4 groups of 8)Module Location 1771ĆA1B thru ĆA4B or later

Page 5 - Requirements

DC (10-30V) Output Module 13Publication 1771ĆIN034B-EN-P - August 2002Conducted RF Immunity IEC 61000-4-610V rms with 1kHz sine wave 80% AM from 150k

Page 6 - Field Wiring Arm

DC (10-30V) Output Module14Publication 1771ĆIN034B-EN-P - August 2002

Page 7 - Connect Wiring to the

DC (10-30V) Output Module 15Publication 1771ĆIN034B-EN-P - August 2002

Page 8 - ATTENTION

DC (10-30V) Output Module16Publication 1771ĆIN034B-EN-P - August 2002Publication 1771ĆIN034B-EN-P - August 2002Supersedes publication 1771Ć5.34 - Oct

Page 9

DC (10-30V) Output Module2Publication 1771ĆIN034B-EN-P - August 2002Reproduction of the contents of this copyrighted publication, inwhole or part, wi

Page 10 - Replacing the Fuses

DC (10-30V) Output Module 3Publication 1771ĆIN034B-EN-P - August 2002ATTENTION!Environment and EnclosureThis equipment is intended for use in a Pollu

Page 11 - RISQUE D'EXPLOSION

DC (10-30V) Output Module4Publication 1771ĆIN034B-EN-P - August 2002!ATTENTIONPreventing Electrostatic DischargeThis equipment is sensitive to electr

Page 12 - Specifications

DC (10-30V) Output Module 5Publication 1771ĆIN034B-EN-P - August 2002The controller or I/O chassis power supply, connected through thebackplane of th

Page 13

DC (10-30V) Output Module6Publication 1771ĆIN034B-EN-P - August 2002!ATTENTIONRemove power from the 1771 I/O chassisbackplane before you install the

Page 14 - DC (10-30V) Output Module14

DC (10-30V) Output Module 7Publication 1771ĆIN034B-EN-P - August 2002Make wiring connections to the module through the field wiring arm(cat. no. 1771

Page 15 - DC (10-30V) Output Module 15

DC (10-30V) Output Module8Publication 1771ĆIN034B-EN-P - August 2002I/O Module GroupsEach module condenses 2 full module groups (32 outputs) into eac

Page 16 - DC (10-30V) Output Module16

DC (10-30V) Output Module 9Publication 1771ĆIN034B-EN-P - August 2002!ATTENTIONObserve proper polarity with dc powerconnections. Reverse polarity, or

Commentaires sur ces manuels

Pas de commentaire