Appendix
D
DĆ1
Bit and Word Descriptions of Block-transfer Data
Control Word for Outputs 0 and 1
Bit
No.
Title Description
17 OE
Output enable bit - set this bit if you want
output 1 turned on when comparisons with
presets 1A and 1B are true.
16 ZT
Zero transition bit - set this bit when you want
output 1 energized during a transition through
position 000.
15 >
Comparison bit for preset 1B
14 =
Comparison bit for preset 1B
13 <
Comparison bit for preset 1B
12 >
Comparison bit for preset 1A
11 =
Comparison bit for preset 1A
10 <
Comparison bit for preset 1A
07 OE
Output enable bit - set this bit if you want
output 0 turned on when comparisons with
preset 1A and 1B are true.
06 ZT
Zero transition bit - set this bit when you want
output 0 energized during a transition through
position 000.
05 >
Comparison bit for preset 0B
04 =
Comparison bit for preset 0B
03 <
Comparison bit for preset 0B
02 >
Comparison bit for preset 0A
01 =
Comparison bit for preset 0A
00 <
Comparison bit for preset 0A
Block-transfer-write Data