Rockwell-automation 1760-xxxx Pico Controller User Manual Manuel d'utilisateur Page 183

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 218
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 182
Publication 1760-UM001D-EN-P - September 2005
Use of Expansion Modules 9-5
Module Status Example
Power can be applied to the expansion unit later than it is applied to
the Pico controller. This means that Pico is switched to Run with the
expansion module missing. The Pico circuit diagram below detects
whether the expansion unit is operational or not.
As long as I14 = 1, the remaining circuit diagram is skipped. If I14 = 0,
the circuit diagram is processed. If the expansion module drops out
for any reason, the circuit diagram is skipped. M1 detects whether the
circuit diagram was processed for at least one cycle after the power
supply switched on. If the circuit diagram is skipped, all the outputs
retain their previous state. The next example should be used if this is
not desired.
Example with LCD Output and Reset of the Outputs
-----------SM1
I14--------[:8
I1-I2------[Q1
Q1
I14-M1-----[:8
-----------SM1
I14--------[:8
I1-I2------[Q1
Q1
I14-M1-----[:8
I14--------[:8
:8---------[D1
RQ1
:8
I14--------[D1
Vue de la page 182
1 2 ... 178 179 180 181 182 183 184 185 186 187 188 ... 217 218

Commentaires sur ces manuels

Pas de commentaire